Doc No: 596005361 Rev.2.5
1
1 + 2
Installation
Montage
Montage
Montaje
Montagem
2
3
3 + 4
Removal
Demontage
Démontage
Desmontaje
Desmontagem
4
39 [1.54]
53.3 [2.10]
2
3
Ө
L/24V
N/
COE
1
2
Control range / Regelbereich / Gamme de réglage /
Rango de ajuste / Faixa de controlo
DC THERMOSTAT (°C)
0 - 60°C, 24 V DC
DC THERMOSTAT (°F)
32 - 140°F, 24 V DC
DC HYGROSTAT (%r.H.)
30 - 90 %, 24 V DC
External sensor + cable for
TEMPERATURE SENSOR
thermostat
External sensor + cable for
HUMIDITY SENSOR
hygrostat
3
Safety Information
These components must be installed / serviced
by
qualified
personnel
complying
relevant safety regulations in force and in
accordance
with
the
wiring
diagram
on the housing / represented in this manual.
Ensure manuals are kept in a secure place
accessible to servicing / installing personnel.
Device description
These devices have been designed specifically for
electrical enclosure temperature/humidity control.
Type
Knob colour
White
Electronic adjustable thermostat
Orange
Electronic adjustable hygrostat
Installation
The
devices
have
been
designed
installation on a DIN EN 60715 compliant rail.
For correct operation note the following:
● Device must be mounted VERTICALLY (do not
mount in any other position)
● Device must be mounted with a minimum of
30mm clearance around it to avoid covering of the
ventilation slots.
● Device must be mounted as far as possible from
heat generating components
Switching capacity
16 A, resistive load
Hysteresis
3K / 5%
Switching tolerance
±5K / 10%
Rate of temperature
max. 1K/min.
change
Operating temperatures:
-25ºC - 70ºC
Thermostats / Hygrostats
-13ºF - 158ºF
-45ºC - 120ºC
Temperature sensor
-49ºF - 248ºF
-40ºC - 85ºC
Humidity sensor
-40ºF - 185ºF 100%r.H.
Connection: 0.5 - 2.5 mm² / 14 - 20 AWG screw
terminal, Housing Material: Plastic UL94V-2
NOTE: To prevent damage to the contacts caused
by rapid switching, the device has a minimum ON
time and minimum OFF time of 2 to 3 minutes.
TO FIT SENSOR: 1. Remove blanking cover using
a screwdriver. 2. Insert centering ring with notch
positioned as shown. 3. Plug in sensor jack (sensor
housing colour must be of same colour as the
knob).
EN
with
the
shown
for
loading

Resumen de contenidos para SoliTherm CC 3015

  • Página 1 Safety Information Control range / Regelbereich / Gamme de réglage / 39 [1.54] 53.3 [2.10] Rango de ajuste / Faixa de controlo These components must be installed / serviced CC 301 qualified personnel complying with DC THERMOSTAT (°C) 0 - 60°C, 24 V DC relevant safety regulations in force and in accordance with...
  • Página 2 Sicherheitshinweise Informations de sécurité Información de seguridad Instruções de segurança Diese Produkte dürfen nur von qualifiziertem L’installation et maintenance de ces équipements La instalación/mantenimiento de estos aparatos A instalação e manutenção devem ser efetuadas Personal entsprechend dem in dieser Anleitung ne doit être effectuée que par du personnel debe de llevarse a cabo solamente por personal somente por pessoal qualificado, de acordo...