SALT WATER TIMER UV-C
HOW IT WORKS
EN
Inside the reactor a UV-C lamp produces radiation with a wavelength of 253.7 nm. Radiation of this type
kills bacteria, viruses, algae and fungi (e.g. Legionella and Cryptosporidium). The UV-C unit produces
clean, fresh, clear water in an efficient, environmentally friendly way. The water is fed through the
UV-C device by a pump. The UV-C radiation neutralizes bacteria, viruses and other micro-organisms
and prevents them from reproducing. Floating algae is also destroyed by this radiation, which greatly
improves the clarity of the water. The UV-C unit is equipped with an electronic ballast. This ballast
ensures optimum performance of the lamp.
Thanks to the UV-C unit, the water is disinfected efficiently and safely, providing you with excellent water
quality. Overdosing with UV-C is not possible.
INSTALLATION OF EARTHING (DRAWING 1)
1. Before the plastic strain relief (4) is fitted on the earthing bolt (1), first pull the cable (2) through
the strain relief (4). Place the strain relief (4) about 10 cm from the eye (2) of the earthing cable.
2. Place the eye (2) of the cable over the earthing bolt that is attached to the housing.
3. Then place a serrated lock washer (3).
4. Attach the strain relief (4) to create a Ø5 cm loop.
5. Finally, place the second serrated lock washer (5) and the lock nut (6) on the earthing bolt.
6. Once the parts have been placed on the earthing bolt in the correct order, it can be tightened
with an 8 mm open-end or ring spanner.
WARNING:
DEVICE INSTALLATION (FIGURE 2)
Decide where you want to mount the device. Never install the UV-C unit after the pH controller, chlorine
dispenser or salt electrolysis system in the swimming pool installation. The best place to install the device
is directly after the filter. See the schematic diagram in the operating instructions. Make sure there is
always water flowing through the device when the lamp is on. Never install the device in direct sunlight.
Install the device in a dry, well-ventilated area. The device can be installed either horizontally or vertically,
provided that the water flow is from bottom to top (see schematic diagram at the beginning of the
instructions for use), with 30 cm of unobstructed space on the side opposite the lamp connection for
future maintenance. At least one metre of unobstructed space must be left on the side with the lamp
connection for convenient future replacement of the lamp (K) without having to disconnect the entire
device.
8
| SALTWATER TIMER UV-C
Please read through these instructions for use
carefully before installing this device.
Always ensure proper earthing. In case of doubt about the earthing or the electrical
installation in general, always consult a qualified electrician. Incorrect earthing can be
dangerous and/or lead to corrosion of stainless steel or aluminium reactors.
Make sure the reactor is always grounded.