Use fresh high quality unleaded gas.
GAS
Add stabilizer to fuel tank and run engine for 5 minutes before storage.
Engine oil: Refer to engine owners manual supplied with this unit.
OIL
Use only cold water.
Do not operate unit with clogged or missing water filter/screen.
WATER
Do not operate unit without adequate water supply to pump. Adequate
water supply is a minimum of 20 psi and 5 gpm.
The pressure setting is preset at the factory to achieve optimum cleaning.
PRESSURE
If you need to lower the pressure setting, refer to the operation manual for
ADJUSTMENT
proper procedure.
Pull gun trigger every 2 minutes while engine is running.
Do not allow water to freeze in pump.
PUMP
For cold weather or long term storage refer to the operation manual for
proper procedure.
Never leave unit running for more than 2 minutes without pulling gun
-
BY
PASS MODE
trigger; doing so could cause damage to pump and void warranty.
Pump is equipped with a thermal relief valve. If the water overheats, this
THERMAL
valve will open and allow a gush of water to escape. Once the water is
RELIEF VALVE
released, the valve closes allowing the pump to operate normally.
Do not allow hoses to contact the HOT engine muffler during or after use.
HOSE
Never pull the hose to move the unit.
Do not adjust or attempt maintenance without consulting engine manual
or an authorized engine service center.
ENGINE
Add stabilizer to fuel tank and run engine for 5 minutes before storage.
Always turn on the water before starting the engine.
/
SOAP
CHEMICALS
Use only soaps and chemicals designed for pressure washer use.
Keep nozzle unclogged. Refer to manual for cleaning procedures.
Chemical/soap cannot be applied in high pressure setting. Only in low
NOZZLE
setting.
Follow recommended maintenance schedule for engine & pump. Refer to
MAINTENANCE
manuals.
SCHEDULE
Draw clean water through chemical inlet.
Add stabilizer to fuel tank and run engine for 5 minutes before storage.
STORAGE OR
Do not allow water to freeze in pump, gun, wand or hoses.
WINTERIZING
For cold weather or long term storage refer to the operation manual for
proper procedure.
ALWAYS REFER TO THE MANUALS SUPPLIED WITH THIS UNIT
D27935
All manuals and user guides at all-guides.com