3.
Adjust slipfitter to the desired angle by loosening the
center hex bolt enough to rotate and adjust. Retighten
the center hex bolt to 120 in-lbs. to secure. (Figure 4.)
N
ote:
Fixture suitable for down mount only. Do not tilt
above 45 degrees from horizontal.
Hex Head Bolt
Figure 4.
4.
Reinstall slipfitter cover plate via two Phillips head
screws. (Figure 2.)
5.
Connect luminaire to supply wires:
a. Connect supply side line voltage to black lead.
b. Connect supply side neutral wire to white lead.
c. Connect supply side ground wire to green lead.
6.
Remove the slipfitter through bolt and install slipfitter
onto 2-3/8" O.D. tenon. Be careful not to pinch any
wires and tighten the four Allen head set screws to 30
in-lbs. (Figure 5.)
Allen Head Screws
Through bolt
Figure 5.
Installation Instructions – LAS Area / Site
7 .
If mounting to a horizontal tenon, reinstall the through
bolt to secure fixture to tenon. Tighten through bolt to
120 in-lbs. (Figure 5.)
PHOTOCONTROL / SHORTING CAP INSTALLATION
1.
Insert provided photocontrol (or shorting cap) into the
receptacle and twist into locked position. (Figure 6.)
Figure 6.
MOTION SENSOR LENS INSTALLATION
(IF APPLICABLE)
1.
Remove the clear plastic cap that covers the motion
sensor receptacle on the fixture.
2.
Twist to install the provided motion sensor lens onto
receptacle until secure. (Figure 7 .)
Motion Sensor Lens
Figure 7.