Powering The Unit - Behringer KLARK TEKNIK DN9650 Puesta En Marcha

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
14
DN9650/DN9652
DN9650/DN9652 – Getting Started

Powering the unit

This section shows you how to connect the unit to the mains, switch the unit on/off and electrically isolate
the unit.
The internal power supplies are of the switch mode type that automatically sense the incoming mains voltage
and will work where the nominal voltage is in the range 100VAC to 240VAC.
>> To switch the unit on/off
Making sure that the mains power at the power outlet is off, connect the mains cable supplied with your
DN965X to the mains power outlet and then to the mains socket at the rear of your unit. To switch the unit
on/off, use the mains on/off switch on the rear of the unit. The blue KT roundel on the front of the unit will
illuminate to show that power is on.
To electrically isolate the unit, switch it off and remove the mains cable from mains IEC socket on the
rear panel.
Configuring the unit
Important:
Before you use the unit for the first time, you must configure your computer with the IP address
for the first time
and netmask to suit the range used by the DN965X.
Before you can use the DN965X as a network bridge, you must first configure it by choosing the type
of network module card(s) that are fitted in the unit and then setting them up. Configuration involves
connecting the DN965X to a computer running an up-to-date web browser. To make sure your computer
is compatible with the DN965X, you will need to change its IP address and netmask. For more information
on configuration, see user manual.
>> To connect the DN965X to a computer and then open its configuration menu in the
web browser
(1) Connect an Ethernet cable to the CONTROL socket on the rear panel of the DN965X and then to the
Ethernet port of your computer.
Laptop PC/Mac
Connecting a DN965X to a computer
(2) Switch on the DN965X and your computer. (Note the default IP address of the DN965X, which is
displayed on its LCD screen during power up.)
(3) To make sure your computer is compatible with the DN965X, we recommend that you change the IP
address and netmask of your computer to 192.168.2.1 and 255.255.0.0, respectively; for instructions,
refer to your computer's help and support information.
(4) Open your computer's web browser.
Note: Make sure your web browser is up-to-date.
(5) In the web browser's address bar, type in the
following default IP address (displayed on the
unit's LCD screen during power up) and then
press ENTER:
"http://192.168.10.10"
Ethernet cable
CONTROL
connector
Typical browser address bar
(6) The DN965X NETWORK BRIDGE CONFIGURATION menu will open in the web browser's Klark Teknik
DN965X Configuration tab.
>> To select which network card(s) are fitted in the unit
(7) In the configuration menu, click Change Module Type in the desired network module section. If no
network module type has been set up, its section will look similar to the one shown below. On the
DN9650, network module B is always a Klark Teknik 3-Port AES50 Module.
(8) In the Change Network Module Type window, select the appropriate network module type and then
click OK.
(9) Your DN965X is now ready for use as a network bridge. However, if you want to change the settings of
the network module cards, see "Setting up a network module" on page 19
For more information about the operation of this product, visit klarkteknik.com and
download the full Operator Manual.
15
Quick Start Guide
Tabla de contenido
loading

Este manual también es adecuado para:

Klark teknik dn9652

Tabla de contenido