Caution:
Ensure adequate ventilation when charging the bat-
tery.
Notice:
The product safety data sheet provided by the bat-
tery manufacturer must be observed.
Notice:
The operating instructions provided by the battery
manufacturer must be met.
Caution:
Always disconnect the batteries from the machine
before starting maintenance work.
Battery connection diagram
AERO 3500µicro (Gel)
6V batteries
Charger
red
100A
black
12V batteries
Charger
red
100A
black
6
6 V
6 V
6 V
6 V
12 V
12 V
AERO 3500µicro (Lithium)
Charger
Charger
Mains
external
internal
Battery
plug
Drive direction
Forward
Power Board
red
black
Charging process
Caution:
Please pay careful attention to the instructions of
use provided by the manufacturer of the external
battery charging device.
Caution:
Each battery type and/or battery manufacturer re-
quires different charging characteristics.
Incorrect charging characteristics or the use of inappro-
priate chargers may result in early failure or the quick
destruction of batteries.
Notice:
Optionally available on-board chargers are adapted
to the battery size and contain several charging
curves, which are adjusted ex factory or by a TASKI
service technician for recommended batteries. This
regulation also applies for the use of stationary (ex-
ternal) chargers.
Caution:
Persistent short-term use with subsequent battery
charging may cause long-term damage to the bat-
teries.
- Standard value: At least approx. 20% of the available
capacity should be used up before recharging the bat-
tery.
Caution:
In order to achieve the maximum possible service
life, traction batteries must run through a complete
charging cycle (12-16 hours) twice a week.
Caution:
Before decommissioning the machine for a longer
period, the batteries must run through a complete
charging cycle. The charger is then disconnected
from the machine and/or mains. Batteries gradually
discharge. Depending on the type of battery, they
must be recharged after 3-6 months.
- Before recommissioning, the batteries should run
through another complete charging cycle.
Mains
Relay
25.6 V