DESCRIPTION OF CHARACTERISTICS AND OPERATION

The "MAXI UP" dosing pumps series are ideal for dosing acid and chlorine in small, medium and large pools.
They can operate in Manual, ON-OFF and Proportional mode and the flowrate is adjustable from 10% to 100% of the
maximum flowrate. They can adjust the flowrate by varying the rotation speed of the roll holder.
In standard version pumps it is possible to set a "delay on" switching on that allows to stabilize the measurement before
dosing, it is possible to set an overdose alarm ("TAL"), equipped with a peristaltic tube break sensor which, in case of
chemical leaks, blocks the dosage.
THE FIRST THING TO DEFINE ON THE MAXI UP PUMP IS IF THE PUMP MUST MEASURE PH OR RX.
See page 28: Set up menu → MEASURE

FRONT PANEL DESCRIPTION

1.Display LCD 16 x 2 backlight
2.Green Led: ▪ fix = PUMP ON
▪ blinking = PUMP IN ALARM
3.Red Led: indicates the injections of chemical dosing
4.ENTER/MENU button : ▪ allows to enter in programming

GENERAL FUNCTIONS

- REAL TIME pH or RX MEASURE
- REAL TIME FLOW RATE% VISUALIZATION
- 3 POSSIBLE TYPES OF DOSAGE: MANUAL, ON / OFF, PROPORTIONAL
- MENU IN 4 LANGUAGES: ENGLISH, FRENCH, SPANISH, DUTCH
- POSSIBILITY TO INSERT A PASSWORD
- DELAY ON SWITCHING
- OVER DOSAGE TIME ALARM
- PRIME BUTTON
- RESTORATION OF DEFAULT PARAMETERS AND FACTORY CALIBRATION
- DOSAGE STOP (STAND_BY)
- WATER FLOW SENSOR ALARM
- CONTROL OF PRODUCT END LEVEL
- HOSE BREAKAGE SENSOR
Rev 0.3
▪ saves the changes
Cod. 00.009.157
5. ESC/SBY button: ▪ allows to exit from the menu
▪ puts the pump in stand_by mode
6/7. ▲▼ buttons : ▪ allow to navigate through the menu
▪ allow to modify the parameters values
8. Prime button: ▪ allows to prime the pump