Model: 37792 / ZW5307
ADVANCED OPERATION
The following Advanced Operation parameters require that you have an advanced controller.
Basic controllers do not have this capability.
Adjust Refresh
Parameter No: 21
•
Length: 1 Byte
•
Valid Values
•
•
0 (Default – 10 Seconds)
1 – 55 (Seconds)
•
Z‐Wave Plus Interoperability Statement
This product can be included and operated in any Z‐Wave network with other Z‐Wave certified devices from other
manufacturers and/or other applications. All non‐battery operated nodes within the network will act as repeaters
regardless of vendor to increase reliability of the network.
Association Group Statement
This device supports Association Command Class (1 Group)
•
Association Group 1 supports Lifeline, Battery Reports, Device Reset Locally Notification
Association Group supports 2 devices
•