  • Página 2: Electrical Specifications

    Electrical Specifications 25733, 25735 Clear Power 24VAC Class 2 Only 35541, 35540 Tinted 24 VAC 3.7 Amps 89 Watts Accessories: Heater: 50 Watts/Blower: 2 Watt Camera Power: Up to 37 Watts English Tools Required: .100” Flat Head Screwdriver Phillips Head Screwdriver Note: 25735 includes no accessories 24 VAC 3.7 amperios...
  • Página 3: Important Safeguards

    IMPORTANT SAFEGUARDS SAFETY PRECAUTIONS 1. Read Instructions - All the safety and operating instructions should be read before the unit is operated. C AUTION 2. Retain Instructions - The safety and operating instructions R ISK OF should be retained for future reference. ELECTRIC SHOCK ! 3.
  • Página 4 Wrap Teflon tape around the pipe threads Securely mount bracket to wall. Pull wiring to ensure a tight seal. through bracket and position grommet as shown. • Con seguridad soporte del montaje a emparedar. Tire del cableado • La cinta del Teflon del abrigo alrededor de la pipa rosca a través del soporte y del ojal de la posición según lo demostrado.
  • Página 5 Loop the lanyard over the set screw to Make the appropriate wiring connections temporarily hold housing. from the dome to the pendant. • Coloque el acollador sobre el tornillo de presión para • Hacer las conexiones de cableado de la cúpula de la celebrar temporalmente la cubierta.
  • Página 6 RJ45 24VAC POWER Camera 25 Watts Camera Orange Heater/Blower Yellow 26 Watts Heater/Blower Green Alarm 1 Blue Alarm 2 Violet Alarm 3 Gray Common White Make the appropriate male and female connections. Indoor model does not include pre-run cables. • Haga las conexiones masculinas y femeninas apropiadas. El modelo de interior no incluye pre-funciona los cables. •...
  • Página 7: Mounting Plate

    Axis 213 (3) #8x3/8” ½" Mounting Plate 1" Captive Screw 2" MOUNTING HOLE Install the camera to the mounting plate with (2) #10 screws and lock washers provided. Place (3) #8x3/8” screws on the spacers and align the mounting slots. Slide on plate and camera then secure. •...
  • Página 8 Axis 215 1" 1" 2" Mounting Holes Attach camera to quick release plate as shown. Use spacers to assemble (4) 3” legs. Secure camera into position. • Una la cámara fotográfica a la placa rápida del lanzamiento según lo demostrado. Utilice los espaciadores para montar (4) las piernas del 3".
  • Página 9 Connection Module Screw Power Board To remove the power board, use screwdriver to release plastic fasteners by applying pressure to sides while pulling out. This is what the typical path of illumination will look like with the setting at 30 degrees. Attach connection module as shown.
  • Página 10 CAMERA POWER Camrea Specification Camera Power Camera Power (at 24VAC REQUIRED) 12VDC 37W 24VAC 12VDC 20W 24VAC 14.5W 12VDC 20W 24VAC POWER PLUG 231/232 25W 19-20VAC 25W 24VAC 18-30VAC 25W 24VAC Camera specification for 24VAC outdoor housing. No electronics are included with indoor unit. For 12VDC unit connect power plug and ethernet cables into camera.
  • Página 11 Axis 233D Remove power board. Use secrewdriver to release plastic fasteners by applying pressure to sides while pulling out. Construct mounting bracket assembly and attach camera. • Quitar poder bordo. Uso de liberar secrewdriver Sujetadores de plástico mediante la aplicación de presión a los lados Mientras tira.
  • Página 12 Axis P5534 (3) #8x3/8” ½" Axis Locking Plate 1" Quick Release Plate Captive Screw Mounting Bracket MOUNTING HOLE Assemble Axis locking plate to quick release plate using (3) #8 bolts, washers and nuts. Connect the combined plates to the bracket and housing using (4) 1” and (4) ½” spacers and #8 bolts. Insert camera onto mounted locking plate and turn clockwise to lock in position.
  • Página 13 Wipe the dome clean. Fasten down the dome with a Phillips screwdriver. • Sujete abajo de la bóveda con un destornillador Phillips. • Limpie la bóveda limpia. • Attachez en bas du dôme avec un tournevis Phillips. • Essuyez le dôme. •...
  • Página 14: Replacement Parts List

    Replacement Parts List 25733 Part Number Description RPFD7501 Lower Trim Ring (Long) RCTFD7 Tinted Replacement Capsule RCFD7 Clear Replacement Capsule RPFD703 Dome Clamping Bracket RPFD072 24 Vac Heater RPFD080 (12 Vdc) Blower (Used In 24v Housings) RPFD060 Camera Bracket RPRH707 Connection Pcb RPFD040 Housing Hardware...