Combustion chamber cleaning

Remove the residues from the combustion chamber with a suitable ash vacuum, ensuring that the ash is
completely extinguished.
The combustion chamber of these Ravelli products is lined with refractory stone tiles. Refractory stone does not require any particular
maintenance, it only needs to be dusted with a brush if you wish to remove any ash that deposited during combustion.
It is not recommended to use abrasive sponges to clean stubborn build-up as this could scratch the surface.

Combustion grille cleaning

To clean the combustion grille correctly, move the combustion grille shaker lever back and forth, so that the grille makes small rotating
movements and clears the holes for air flow. This will make the ash that has accumulated during combustion drop into the drawer
below.

Cleaning the ash drawer

The ash drawer must be cleaned every 30 days, (depending on the amount of time the stove is used and what type of wood is used).
To clean the ash drawer, proceed as follows:
.
Open the door (Alba, Alba steel).
1
Open the bottom door (Lia, Lia steel).

Glass cleaning

With a cold stove, clean the glass with a cloth and glass cleaner.
Note: there are stove glass cleaning products available on the market.

Removing the rotating grille and fire grate

To make cleaning easier, it is possible to remove the rotating grille and fire grate. To remove the parts, open the stove door and
take them out by lifting them out of place.
Use and maintenance manual Alba- Alba steel- Lia- Lia steel
2
Pull out the drawer as shown in the figure.
Remove the ash with an appropriate ash
vacuum.