CALL FORWARDING DEVICE GCALL/GTWIN
SAFETY PRECAUTIONS
( )
*
-
Always disconnect the power supply
before installing or making modifications to the device.
- The fitting and handling of these devices must be carried out by authorised personnel.
- The wiring must run at least 40 cm away from any other wiring.
- Do not overtighten the screws on the connector.
-
Install th
e device
in a dry and protected place free from the risk of water leaks or sprays.
- Avoid locations that are humid, dusty or near heat sources.
- Ensure that the air vents are free from obstruction so that air can circulate freely.
- The device must be installed in a Electric Panel.
- To avoid damage, th
e device
must be firmly secured in place.
- To prevent electric shock in installation with
cover or handle the wiring connected to
power supply
DESCRIPTION OF GCALL/GTWIN DEVICE
( )
*
STATUS
V.INT
24V
+
1
2
5
3
1-
Status LED:
Internet connection.
Flashing red light: configuration mode.
•
Steady green light: the device has been correctly
•
registered with the Golmar SIP server and is
ready to forward calls to a Smartphone.
Flashing green light: the device is in Upgrade
•
mode.
Steady red light: the device is showing that there
•
is no Internet connection.
Steady orange light: device not enabled (no
•
active Wi-Fi).
During power-on or after pressing the PROGR/
RESET key, the device will need 50s to start up;
during this time, the LED will remain off.
2-
PROGR/RESET key:
By pressing the button for a
time.
Between 2s and 4s, the device will restart in the
•
configuration mode (maintaining any parameters that
had already been configured).
Shorter than 2s or longer than 4s, the device will be
•
restarted.
After 5 short consecutive presses (at time intervals
shorter than 1s) the device will restore its factory
parameters and signal the event with a flashing
red/orange/green LED light, to then switch to the
configuration mode.
After 3 short consecutive presses (at time intervals
( ) For more information, see the "T
GCALL/GTWIN ML"
*
https://doc.golmar.es/search/manual/50124023
external local power supply FA-GCall
, do not remove the
terminals
or
GCALL/GTWIN device
terminals
V.EXT
LINE OUT LINE IN Z
CODE
4
6
7
8
shorter than 1s) the device switches to Upgrade
mode. The green LED will blink continuosly to
indicate the event.
3-
LAN connector:
Ethernet port for wired
connection to the home network.
4- Device power supply:
V.INT
Power from Bus line
(Default).
Power from local external power
V.EXT
supply
(FA-GCALL, see manual 50122357).
+/-24V Terminals:
5-
External local power supply.
LINE IN, LINE OUT terminals:
6-
Connection to the
system bus.
7-
Jumper Z
: Line termination setting. Line termination
must be activated on a device connected at the
end of a line without a new section restarting from
the LINE OUT terminals.
DIP switch CODE:
8-
Define the number of the
apartment in the column:
Dip 1: Remain set to OFF.
•
Dip 2 a 8: define the apartment number (code) in
•
ON
the column.
O N
See system manual
=
Code 50122345.
user manual (code 5012
4023
)".
2
CALL FORWARDING DEVICE GCALL/GTWIN
INSTALLATION IN A CONTROL PANEL
( )
*
1- Insert the spacer behind the device in its special
seat, ensuring that it is locked by the lever . A
.
3- Remove the terminal strip cover.
2
( )
WIRING DIAGRAM
*
LINE OUT
LINE
LINE
3
Z=OFF
LINE
LINE
2
LINE IN
OFF
O N
( )
Remove the jumper from all distributors except the last one.
1
=
( )
For more information, see the "TGTWIN MANUAL SISTEMA" manual (code 50122345)".
2
( )
For more information, see the "T
*
https://doc.golmar.es/search/manual/50124023
2- Insert the retainers
in such a way that the terminal strips of the device
are pointing downwards, then insert the retainers . C
1
2
A
4-Connect the assembly to the system.
5-Carry out the device configuration by
6-Replace the terminal strip cover.
7-Power on the device.
8-Complete your parameter configuration by
3
1
TO NEXT DISTRIBUTORS
LINE IN
DISTRIBUTOR
D4L-GTWIN
( )
( )
1
2
Floor Call
CP
Button
S+
4
S-
2
LINE OUT
LINE IN
1
24Vcc
LAN
To router/modem ADSL or 3G/4G.
FROM PREVIOUS DISTRIBUTORS
GCALL/GTWIN ML"
user manual (code 5012
3
B
of the spacer in the DIN rail
C
B
C
B
means of jumpers and/or DIP switches.
using the Golmar Gcall App.
MAIN
MONITOR
( )
2
LINE OUT
JP Z: ON
CALL FORWARDING GCALL
( )
*
JP V.INT/V.EXT: V.INT
JP Z: OFF
DIP1: OFF
4023
)".