RFSAI-62B
Dual Band wireless switching component input button
EN
Unidad inalámbrica de conmutación de dos canales
ES
(entrada externa)
Technical parameters /
Especifi caciones técnicas
Supply voltage:
Apparent power:
Dissipated power:
Supply voltage tolerance:
Output
Number of contacts:
Rated current:
Switching power:
Peak current:
Switching voltage:
Min. switching power DC:
Mechanical service life:
Electrical service life (AC1):
Controlling
RF command from the transmitter:
Manual control:
External button:
Range in open space:
Other data
Voltage of open contact:
Resist. of connection for closed
contact:
Resist. of connection for open
contact:
Galvanic isolation of input:
Operating temperature:
Working position:
Mounting:
Protection:
Overvoltage category:
Contamination degree:
Terminals (
Terminal length:
Dimensions:
Weight:
Related standards:
↯
* Control button input is at the supply voltage potential.
Attention:
When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units.
Between the individual commands must be an interval of at least 1s.
Warning
Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Instal-
lation and connection can be carried out only by a person with adequate professional qualifi cation upon under-
standing this instruction manual and functions of the device, and while observing all valid regulations. Trouble-free
function of the device also depends on transportation, storing and handling. In case you notice any sign of damage,
deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat
this product and its parts as electronic waste after its lifetime is terminated. Before starting installation, make sure
that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regula-
tions, norms, directives and professional, and export regulations for working with electrical devices. Do not touch
parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe correct location of
RF components in a building where the installation is taking place. RF Control is designated only for mounting in
interiors. Devices are not designated for installation into exteriors and humid spaces. The must not be installed into
metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is then impossible.
RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an obstruction, inter-
fered, battery of the transceiver can get fl at etc. and thus disable remote control.
ELKO EP ESPAÑA, S.L. | C/ Josep Martinez 15a, bj | 07007 Palma de Mallorca | e-mail:
[email protected] | Tel.: +34 971 751 425 | Fax: +34 971 428 076
Made in Czech Republic
Tensión de alimentación:
Consumo aparente:
Consumo de perdida:
Tolerancia de alimentación:
Salida
Número de contactos:
Corriente nominal:
Potencia de conmutación:
Pico de corriente:
Tensión de conmutación:
Conmutación de potencia min.DC:
Vida mecánica:
Vida eléctrica (AC1):
Control
Orden RF desde controlador:
Control manual:
Con pulsador externo:
Rango al aire libre:
Más información
Tensión del contacto abierto:
Resistencia del cableado para
pulsador en pulso:
Resistencia del cableado para
pulsador sin pulso:
Aislamiento galvánico de entrada:
Temperatura de funcionamiento:
Posición de funcionamiento:
Montaje:
Protección:
Categoría de sobretensión:
Grado de contaminación:
):
Salida (hilos CY, sección):
CY wire, Cross-section
Longitud de cables:
Dimensiones:
Peso:
Normas conexas:
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech Republic | e-mail:
[email protected] | Support: +420 778 427 366
www.elkoep.com / www.elkoep.es
RFSAI-62B/230V
RFSAI-62B/120V
230 V AC / 50 - 60 Hz
120 V AC / 60Hz
7 VA / cos φ = 0.1
7 VA / cos φ = 0.1
0.7 W
0.7 W
+10 %; -15 %
2x switching / NA (AgSnO
8 A / AC1
2000 VA / AC1, 192 W / DC
10 A / <3 s
250 V AC1 / 24 V DC
500 mW
7
1x10
5
1x10
866 MHz, 868 MHz, 916 MHz
button PROG / botón PROG (ON/OFF)
max. 12 m cable / del cable *
up to / hasta 200 m
2.5 V
<1 kΩ
>10 kΩ
↯
no / no
-15 ... + 50 °C
any / cualquiera
free at lead-in wires / libre en los cables de conexión
IP30
III.
2
3x 0.75 mm
2
, 1x 2.5 mm
2
90 mm
49 x 49 x 21 mm
46 g
EN 60669, EN 300220, EN 301489 R&TTE Directive, Order. No 426/2000 Coll. (Directive 1999/EC)/
EN 60669, EN 300 220, EN 301 489 directiva RTTE, NVč.426/2000Sb (directiva 1999/ES)
↯
* Entrada del pulsador de control está en el potencial de la tensión de red.
Advertencia:
En la instalación de iNELS RF Control debe haber una distancia mínima entre las diferentes unidades
de un centímetro.
Entre los diferentes ordenes debe pasar al menos 1s.
Advertencia
El manual de uso está dirigido para la instalación y el usuario del dispositivo. Manual siempre está incluido en
embalaje. La instalación y conexión puede realizar sólo personal con adecuadas cualifi caciones profesionales, de
conformidad con todas las regulaciones aplicadas, y que está perfectamente familiarizado con estas instrucciones
y funciones del dispositivo. Función del dispositivo también depende del transporte, almacenamiento y la manipu-
lación. Si se observa cualquier signo de daño, deformación, mal funcionamiento o pieza que falta, no instale este
producto y devolvelo al vendedor. Con el producto y sus componentes debe ser tratado después de su vida útil
como con residuos electrónicos. Antes de iniciar la instalación, asegúrese de que todos los cables, partes o termi-
nales conectados están sin la conexión a la red. En el montaje y el mantenimiento se deben observar las normas de
seguridad, normas, directivas y reglamentos para trabajar con equipos eléctricos. No toque las partes del dispositivo
que están conectadas en la red - puede producir peligro de vida. Debido a la transmisibilidad de la señal RF, observe
la correcta ubicación de los componentes RF en un edifi cio donde la instalación se lleva a cabo. RF Control está
diseñado para montaje en interiores, las unidades no están diseñados para la instalación en exteriores y espacios
húmedos, no se pueden instalar en cuadros eléctricos de metal y en cuadros eléctricos plásticos con puerta de
metal - lo que empeora transmisividad de la señal RF. RF Control no se recomienda para el control de dispositivos
que ofrecen funciones vitales o para controlar dispositivos tales como bombas, el. calentadores sin termostato,
ascensores, montacargas, etc. - Señal de radiofrecuencia puede estar bloqueado por una obstrucción, interferida,
la batería del controlador puede estar ya sin energía, etc. y por lo tanto el control remoto puede ser incapacitado.
02-8/2018 Rev.1
RFSAI-62B/24V
12-24 V AC/DC 50-60Hz
-
0.7 W
)
2
4x 0.75 mm
2
, 1x 2.5 mm
2
7/7