Kenmore 407.53571 Manual De Uso página 14

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Problem
Dehumidifier
does not
start.
PossibleCauses
Solutions
Dehumidifier
is not oper-
ating as
Intended.
The dehumidifier
is un-
plugged.
Filter indicator
is lit.
The fuse is blown / circuit
breaker is tripped.
Dehumidifier has reached
the user set humiditylevel
or the bucket is full.
Make sure the dehumidifier's
p[ug is pushed com-
pletely into the outlet.
Check the house fuse / circuit breaker box and
replace fuse or reset breaker.
i
,,,,,,IIHIH,,,
The dehumidifier
automatically
turns off when either
condition
occurs. Change to a lower setting
or emp-
ty the water
bucket
and replace
properly.
Bucket is not in the proper
The bucket must be in place and securelyseated for
position,
the dehumidifier to operate.
Power Failure.
Not enough time
allowed
for unit to remove
moisture.
There isa protective time delay of 3 minutesto
prevent tripping of the compressor overload. For this
reason, the unit will not start normal dehumidifica-
tion for 3 rain. after it is powered back on.
When first installed, allow at least 24 hours to
achieve the desired humidity level.
Airflow
is restricted.
Make sure there are no curtains, blinds, or furniture
blocking
the side or back of the dehumidifier.
See the Cleaning The Air Filter section
Dirty filter.
The user set Humidity Level
may not be set low enough.
Doors and windows may
not be closed tightly.
Water
is not draining
i through
drain hose
Room temperature
is too
low.
Filter needs to be cleaned
every 250 hours of use.
To reduce
moisture, press the down arrow button to
lower the percent
humidity
desired
in the room, or
set the dehumidifier
to CO for continuous
operation.
Check that all doors,windows, and other openings
are securely closed.
i
,
i ii
lll,l,lrllll
i r
ii
i
Make sure the drain
is placed below
the drain con-
nector nozzle to a!low gravity
to drain
the water
i (Refer to Gravity
Draln Hose section in this manual).
i,
,!
,,
r lrl
iHi
r i r
Moisture removal
_sbest at higher
roam tempera-
tures, Lower room temperatures
will reduce the
moisture removal
rate. This model is designed
to
operate at temperatures
above 41°F.
Once filter has been cleaned, pressthe FILTER but-
' ton for 3 seconds to turn the filter indicator off.
14
Tabla de contenido
loading

Tabla de contenido