TIME OFF
TIME OFF
TIME OFF
TIME OFF
- Press
to set the time when the heat pump stops.
TIME OFF
- When the display comes on and the time flashes, press
- Press
and
to change the settings. Before the display stops flashing, press
minutes.
- Press
and
to change the settings.
- Once you have finished, press
TIME OFF
- After 30 seconds, the display stops flashing.
CANCELLING THE AUTOMATIC MODE
CANCELLING THE AUTOMATIC MODE
CANCELLING THE AUTOMATIC MODE
CANCELLING THE AUTOMATIC MODE
- Press
and
to cancel the Time On and Time Off modes.
- When the number flashes, press the button to set the time
- When the light goes off and the display shows the temperature of the water, the automatic Time On
and Time Off modes are cancelled.
- After 30 seconds, the display stops flashing.
CHECKS
CHECKS - - - - TESTS
CHECKS
CHECKS
TESTS
TESTS
TESTS
- Check the connections of the water pipes.
- Check the position of the valves.
- Check the electric connection and test the 30mA differential protective device.
- Check that the air inlet and outlet are not obstructed.
- Switch on the filter pump (or the auxiliary pump) used to deliver the required water flow in the heat
pump.
- Check for leaks.
- Set the required temperature on the thermostat.
- Use the On/Off switch to switch on the heat pump.
- The compressor starts one minute after the fan.
- Once the machine is running, check for any unusual noises.
MAINTENANCE
MAINTENANCE
MAINTENANCE
MAINTENANCE
!! Disconnect the power supply before working on the machine!!
!! Disconnect the power supply before working on the machine!!
!! Disconnect the power supply before working on the machine!!
!! Disconnect the power supply before working on the machine!!
Wintering
- Disconnect the power supply and drain any water inside the machine by unscrewing the couplings.
- Cover the machine with protective film.
TASKS
TASKS
TASKS
TASKS
Stop the heat pump
Visually check the attachment and the hydraulic
and electrical connections
Check the discharge of condensates
Clean air grids
Check the cut-off devices and the settings of the
digital control panel
Clean the cover with soapy water.
Do not use high-pressure jets or corrosive
products
NOTPACEDG - ind B - 0408
TIME OFF
again to set the hour.
to set the
and the temperature of the water appears.
.
MINIMUM FREQUENCY
MINIMUM FREQUENCY
MINIMUM FREQUENCY
MINIMUM FREQUENCY
For all work on the filter valve
On every visit to the technical premises
Whenever the power supply is cut
Once a year
17 / 17
FAQ
FAQ
FAQ
FAQ
Observation
Observation
Causes
Causes
Observation
Observation
Causes
Causes
No current
Stop button pressed
The heat pump does
The heat pump does
The heat pump does
The heat pump does
No voltage
not start
not start
not start
not start
Circuit breaker tripped
Blocked air inlet
Blocked air outlet
Three-minute defrost
The required
The required
The required
The required
Temperature setting too low
temperature is not
temperature is not
temperature is not
temperature is not
Has not been operating for
reached
reached
reached
reached
long enough
Actual application is different
from the application used in
the cost estimate
Error codes
Error codes
Error codes
Error codes
NO.
Code
Description of the fault
1
EE 1
High-pressure protection
2
EE 2
Low-pressure protection
3
EE 3
Flow rate controller
4
EE 4
Phase order (three-phase machines only)
5
PP 1
Pool temperature sensor (water exchanger)
6
PP 2
Condensation temperature sensor (water exchanger)
7
PP 3
Pressure relief temperature sensor (air exchanger)
8
PP 4
Suction temperature sensor (compressor)
9
PP 5
Air temperature sensor (air exchanger)
10
PP 6
Compressor overload
11
PP 7
Low temperature (water or air) < 5°C, automatic reset
Caution! Do not dismantle or repair the pool heat pump yourself, contact your dealer !
NOTPACEDG - ind B - 0408
Solutions
Solutions
Solutions
Solutions
Measure the voltage. If 0 Volt wait for the
current to return
Press the button
Look for the cause and reset the
protective devices
Look for the cause and reset the circuit
breaker
Clean the air inlet
Clean the air outlet
Please wait
Increase the temperature setting
Increase the filter time and the operating
range of the heat pump.
Check and change the
settings (cover time, required
temperature, period of use, etc.)