6.2. Errores de medición
Símbolo / Parámetro
V / Tensión (true RMS)
I / Corriente (true RMS)
/
Á ngulo (P - Q)
P / Potencia activa
Q / Potencia reactiva
Ea / Energía activa
Er / energía reactiva
Sensor de corriente
NC100A (@0.5A - 100A)
NC600A (@2A - 600A)
NC1200A (@4A - 1200A)
NP150A (@0.5A - 150A)
NP600A (@2A - 600A)
NC100A (@0.5A - 100A)
NC600A (@2A - 600A)
NC1200A (@4A - 1200A)
NP150A (@0.5A - 150A)
NP600A (@2A - 600A)
NC100A (@0.5A - 100A)
NC600A (@2A - 600A)
NC1200A (@4A - 1200A)
NP150A (@0.5A - 150A)
NP600A (@2A - 600A)
NC100A (@0.5A - 100A)
NC600A (@2A - 600A)
NC1200A (@4A - 1200A)
NP150A (@0.5A - 150A)
NP600A (@2A - 600A)
Powermeter SMART - Manual de uso (completo)
Sensibilidad
Resolución
inicial
0.1 V
0.1 V
0.2 A
1 A
0.01 A
2 A
0.3 A
1 A
< 120 minutos
< 30 minutos
< 30 minutos
< 30 minutos
< 30 minutos
1 W
5 W
1 W
20 W
1 W
40 W
1 W
6 W
1 W
20 W
1 VAR
5 VAR
1 VAR
20 VAR
1 VAR
40 VAR
1 VAR
6 VAR
1 VAR
20 VAR
0.01 kWh
0.01 kWh
0.01 kVARh
0.01 kVARh
Error ( % rdg +/- d)
0.5% +/- 1d
0.5% +/- 1d
0.5% de P +/- 3.5% de Q +/- 1d
0.5% de P +/- 0.9% de Q +/- 1d
0.5% de P +/- 0.9% de Q +/- 1d
0.5% de P +/- 0.9% de Q +/- 1d
0.5% de P +/- 0.9% de Q +/- 1d
0.5% de Q +/- 3.5% de P +/- 1d
0.5% de Q +/- 0.9% de P +/- 1d
0.5% de Q +/- 0.9% de P +/- 1d
0.5% de Q +/- 0.9% de P +/- 1d
0.5% de Q +/- 0.9% de P +/- 1d
Ídem P
Ídem Q