The appliance has been tested before being put
into service. The information provided below
is intended to assist in the identifi cation and
correction of any anomalies and malfunctions
which might occur during use.
The user can solve some of these problems
himself, but for others specifi c technical knowl-
edge or skill is required, and so they must only
be carried out by qualifi ed staff with recognised
experience acquired in the specifi c sector of op-
eration.
Faults
The cooking zones do not
turn on
Mains light fl ashes once
every 2 seconds
Mains light fl ashes once
a second
3320010_ut_GB_rev.2

FAULT

TROUBLESHOOTING

For all requirements contact the agents or
the headquarters of Angelo Po which can be
found in the contacts section of the website
http://www.angelopo.com.
Causes
Electrical connection not
made correctly
Power regulator failure
Switch faulty
Pan bottom diameter less
than 12 cm
Unsuitable cookware
Pan not correctly positioned
on the cooking zone
Pan empty
Cooling air duct obstructed
Room temperature too high
- 15 -
Important
Remedies
Contact the after-sales service.
Check the connection of the elec-
trical wires
Wait the auto-resetting.
Contact the after-sales service.
Replace the switch.
Use cookware with the characteri-
stics recommended by the manu-
facturer
Use cookware with the characteri-
stics recommended by the manu-
facturer
Position the pan correctly
Fill the pan
Check the cooling air duct and
clean it if necessary
Contact the after-sales service.
Reduce room temperature