Installation Instructions - aqua-pure AP Easy Serie Instrucciones De Instalación Y Funcionamiento Para El Propietario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS
For Use With Cold Water Only.
NOTE: Remove items from under the sink. Place catch basin there to collect small amount of water that may run out
when disconnecting water supply lines.
1. Turn off cold water supply valve and remove existing water
supply tubing and/or fi tting.
2. Select and mark a location under the sink that allows ac-
cess for fi lter change.
3. Using fi lter head/bracket as a guide, fasten Filter Head As-
sembly to wall with #2 Phillips mounting screws supplied.
Mark hole locations so that there is 1 1/2" between the
screws (see Figure 1), from center of each screw. When
installed, fi lter bottom should be at least 2 1/2" from sink
cabinet fl oor to facilitate cartridge change. Install screws,
but only halfway, so you can easily slip the bracket to wall
before fi rmly setting screws.
4. Determine length of tubing required from fi lter head/
bracket to faucet and from water supply line to fi lter head/
bracket by holding tubing in place ensuring it is of appro-
priate length. Do not kink tubing as this will impede water
fl ow. If necessary, loop tubing around to avoid it being
kinked.
Cut tubing straight with a utility knife. (See Figure 2).
5. Locate the cold water stem on the underside of the faucet
fi xture. Unscrew the cold water feed tube from the faucet
stem. Locate the 1/4" Feedwater Adapter that came with
your Drinking Water System. Insert the black gasket into
the threaded adapter and tighten onto the Faucet Cold Water
Stem under the sink, making sure that 1/4" fi tting is acces-
sible and not facing the wall. Make sure not to over tighten.
Take the Cold Water Feed Tube and attach to the Faucet
Adapter, making sure not to over tighten.
Locate the 1/4" Blue Tubing and insert into the 1/4" Faucet
Adapter (Figure 3). See "Using Push-In Fittings."
Using Push-In Fittings
To Attach Tubing
Push tubing in as far as it will go. Tubing must be inserted past
o-ring and hit backstop. Pull tube to ensure it is secured.
To reduce the risk associated with property damage due to water leakage:
• Ensure all tubing and fi ttings are secure and free of leaks.
Correct
Blue Tubing
To Release Tubing
Push in grey collet to release tubing. With collet
held, pull tubing straight out.
CAUTION
CAUTION
Collet
Backstop
6
Figure 1
Incorrect
Figure 2
Faucet Stem
Undersink
Feedwater
Tube
Figure 3
Tabla de contenido