f. Insert the
other end of
the Outlet
Extension
Tube (3) into
one end of
the Outlet
Extension Tube
Connector (4).
Install the filter cartridges: Hold the NanoCeram® Cartridge with the
7.
label end up and place it into the locking plate on the base. Once inserted
into the base (11), rotate the NanoCeram® Cartridge clockwise slightly to
lock. The Pre-Filter Cartridge inserts into the locking plate at the top of the
NanoCeram® Cartridge the same way.
NOTE: Failure to install appropriate Pre-Filters will greatly reduce the life of
the NanoCeram® Cartridge.
14
g. Insert the
Outlet Line
of the Filter
Base (11) into
the other end
of the Outlet
Extension
Tube
Connector (4).
8.
Attach the inlet assembly: The Inlet Assembly (9) attaches to the top
of the Pre-Filter Cartridge. It is inserted the same way the cartridges
connect. Rotate the Inlet Assembly approximately 1 /8 turn clockwise
and make sure that there are no kinks in the tubes.
9.
Unit start up: Turn on the water supplies, and check for leaks above and
below the sink.
10. Flushing: To flush any residual carbon dust from the filter's
manufacturing process, and to expel air trapped in the filter, turn the
new Side Faucet on. Allow the water to run for 10 Minutes. Check for
leaks.
11. Check installation: Turn the hot and cold taps of the existing faucet on.
Both should work the same way they did before. Check for leaks. Also
turn the Side Faucet on and off, both with the main faucet on, or off. The
Side Faucet should work independently from the main faucet.
15
EN