OPERATION FAULT CODES DESCRIPTION

SYSTEM VOLTAGE AND BATTERY TYPES

The controller identifies the system voltage according to the battery voltage at start-up of the batter , it can also re-identify the system voltage
when it is restarted. Please ensure the voltage displayed in the controller is consistent with the actual voltage, otherwise please check the
battery bank voltage.
The controller has 6 types of conventional battery charging parameters. The controller can identify 12V/24V/48V depending on the model of
the Cedro controller.
Battery type
Battery Voltage
Flooded (FLD)
AUTO
AUTO
Sealed (SEL)
Gel (GEL)
AUTO
AUTO
User (USE)
12/24/36/48V
Ion Lithium (LI)
12/24/36/48V
www.intipv.com
Code
Description
001
Batter overvoltage
002
PV overvoltage
004
Overcharging
008
Over-discharging
010
Battery over-temperature
020
Internal over-temperature
040
PV polarity reversed
080
Battery polarity reversed
011
Load short circuit
012
Load over-power
BST Voltage
14,6V
14,4V
14,2V
14,2V
14,2V
CEDRO CONTROLLER ICC-6048150 / ICC-5048150 / ICC-4048150 / ICC-3048150 / ICC-2048150 / ICC-4024150 USER MANUAL
FLD Voltage
BST_R Voltage
13,8V
13,2V
13,8V
13,2V
--
--
LDV Voltage
LRV Voltage
12,6V
11,0V
12,6V
11,0V
12,6
11,0V
13