Technical Data Table; Trasformation; Instructions For Installation; Installation - Lotus FTC-4EM Guia Para La Intalación E Instrucciones De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

MODELS
DIMENSIONS cm
POWER SUPPLY
MAXIMUM ABSORPTION A
MAXIMUM POWER kW
POWER SUPPLY CABLE
(Silicone)
DIMENSIONS cm
POWER SUPPLY
MAXIMUM ABSORPTION A
MAXIMUM POWER kW
POWER SUPPLY CABLE
(Silicone)
The data plate is on the front panel (see diagram in electric connection item) and has all the data necessary for the
connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishing, etc. , these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
Installation must be carried out observing the following norms:
- Safety prescription in force
- Installation prescription, in force.
The appliance is supplied without the electric connection cable. To install the power supply cable, proceed as follows:
Disconnect the power supply.
Remove the rear panel
Connect the conductor wires to the corresponding terminals in the junction box and fix them into place.
Block the cable with the cable blocked, and reassemble the front panel. The earth wire must be longer than the
others so that if the cable blocked should break, it will disconnect after the tension wires.
N.B. The connection cable must have the following characteristics: it must be at least the silicone type (resistant to a
temperature of at least 180°C, and must have an adequate section for the power of the appliance (see technical data
table).
GB

TECHNICAL DATA TABLE

FTC-4EM
40x65x29h
230Vac 50Hz
11,3
2,6
3x1,5 mm²

TRASFORMATION

INSTRUCTIONS FOR INSTALLATION

INSTALLATION

LAWS, TECHNICAL RULES AND NORMS

ELECTRIC CONNECTION

IE
FTC-6EM
FTC-6ET
60x65x29h
60x65x29h
400Vac 2N
230Vac 50Hz
50Hz
17,8
11,3
4,1
4,1
3x1,5 mm²
4x1,5 mm²
60x65x29h
230Vac3
50Hz
15,6
4,1
4x1,5 mm²
20
FTC-8ET
80x65x29h
400Vac 2N
50Hz
13
5,6
4x2,5 mm²
80x65x29h
230Vac3
50Hz
21,1
5,6
4x2,5 mm²
Tabla de contenido
loading

Este manual también es adecuado para:

Ftc-6emFtc-6etFtc-8et

Tabla de contenido