1. Controls and displays
1.
Air intake opening (both sides)
2.
Air sensor
3.
Air outlet opening
4.
Display and operating display
5.
Front panel
6.
Top speed button:
On/Off of the maximum fan speed
7.
Anion button:
Ion Generator On/Off - An ion generator produces negatively charged
ions (anions) and small amounts of ozone. This increases the
puri cation performance, as the anions combine with positively charged
dirt particles in the room air to form larger clusters. These can then be
ltered out more easily by the internal lters.
Warning - Ozone
Do not use this function if you are sensitive to ozone, in bedrooms, in
rooms where children are present and in rooms with tobacco smoke.
Pets might also feel disturbed.
8.
Speed button: Fan speed level 1 - 2 - 3
9.
Timer button: Running time preselectable from 1 - 12 hours
10. Mode button: Switching between the operating modes:
Automatic - Sleep - Manual
11. Auto button: The device regulates the fan speed independently
according to the air quality
12. Sleep button: All displays except the Sleep display go out and the
device operates in whisper mode to allow undisturbed sleep.
13. ON/OFF button: After connecting the device to a power socket, the
ON/OFF display ashes.
• Touch the button to start the device in Top Speed mode - Select the
desired operating mode via the Mode button (10).
14. Control lights
Remove HCHO: Cleaning for formaldehyde is active (always active)
Purify: Cleaning for ne dust is active (always active)
Anion: lights up when the anion function has been activated via
button (7)
Sleep: lights up when Sleep mode (12) has been activated
Replace Filter: lter change indicator. The air puri er calculates a
required lter change according to how long it has been used. The
change indicator then lights up. The lter should then be replaced to
ensure su cient air puri cation.
• With daily use, the combi- lter should be used up after approx. 6 - 12
months.
• Since the lter contains all the collected pollutants, it should only
be changed outdoors and with appropriate care against contact
contamination (gloves/respiratory protection).
• The lter is not washable.
• An unpleasant odour during operation may indicate that ltered
substances are decomposing in the lter (e.g. bacteria) and it needs to
be replaced or ventilated in the sun.
• Vacuum the lter and the inner housing every 1 to 2 months to remove
coarse dirt. Then place the lter outdoors in direct sunlight for approx.
3 hours to dry it and eliminate any bacteria, viruses etc. that may be
present through the UV rays.
• Also hold the vacuum cleaner to the sensor opening (2) to clean it.
• The lter can then possibly be reused. The lter must be replaced after
1 year at the latest. On the one hand, there is a risk that it will no
longer completely remove the particles mentioned from the air or that
the pollutant particles already in the lter will be released again. The
activated charcoal also loses its effect when unpacked.
2
• Auto: Automatic mode selected via the Auto button (11). The built-in
air quality sensor controls the fan speed.
15. Reset button: After changing the lter, reset the display by pressing the
Filter reset button (15) on the remote control.
16. Displays
Speed: Display of the set fan speed level
PM 2.5: in µg/m³; display of measured ne dust particles with an
aerodynamic diameter Ø 2.5µm (0.5 to 3.5µm). Typical concentrations
in homes are 20 to 30 µg/m³.
Air Quality: After switching on the device, the display ashes until
the sensor has warmed up. After that, the display visually shows the
indoor air quality.
Green stands for good quality
Orange stands for normal quality
Red stands for inadequate quality
If the humidity in the room is very high, condensation can form on
the sensor and negatively affect the display and cause switching back
and forth in automatic mode. In this case, use the air puri er with the
manual speed setting.
Temp: Display of the room air temperature
Timer: Display of the running time preselected via the Timer button (9)
2. Explanation of warning symbols and notes
Risk of electric shock
This symbol indicates a risk of electric shock from touching product parts
carrying hazardous voltage.
Warning
This symbol is used to indicate safety instructions or to draw your attention
to speci c hazards and risks.
Note
This symbol is used to indicate additional information or important notes.
3. Package contents
• 1 air puri er
• 1 combi lter
• 1 remote control
• These operating instructions
4. Safety instructions
• The product is intended for private, non-commercial use only.
• The product is intended only for use inside buildings.
• Use the product only for the intended purpose.
• Protect the product from dirt, moisture and overheating and use it in dry
rooms only.
• Always pull directly on the plug when disconnecting the cable, never on
the cable itself.
• Do not use the product in the immediate vicinity of heaters, other heat
sources or in direct sunlight.
• As with all electrical products, this device should be kept out of the reach
of children.
• Do not operate the product outside the power limits speci ed in the
technical data.
• Do not use the product in areas in which electronic products are not
permitted.
• Do not use the product in a damp environment and avoid splashing water.