Operation instruction turbodevil surface cleaner
turbodevil heart shape surface cleaner
Item no.: 710 100 122

Scope of supply

This turbodevil is delivered without nozzles. 6 nozzles 1/4" M with 15° spray angle are required.

Cleaning and maintenance

Please do not clean this device by means of high pressure jets. Please use a customary cleaning agent.
Assembly
1. Please screw 6 nozzles (nozzles 1/4" M with 15° spray angle are required) into the rotating arm. Please plug your spray gun
into the connection and screw it tight.
2. The high pressure cleaner can now be connected and the device is then ready for operation.
Possible malfunction
Malfunction: The device does not work with full power
Reason:
The nozzles are possibly blocked
Remedy:
Please screw the nozzles out of the rotating arm and clean them by means of a bent up paper clip (fig. 1).
Afterwards the high pressure hose and the rotating arm should be rinsed under clear water. Please reassemble
your surface cleaner and it should work as good as before.
If the wall cleaner does not work smoothly again it is time to check the high pressure cleaner then. Therefore,
please carefully read the user manual of your high pressure cleaner or contact the distributor or manufacturer of
the high pressure cleaner.

Technical Specifications

model with
1/4" F
rubberlip
Min. / Max. pressure 150 / 350 bar
Max. temperature
5 - 90 °C
Splash guard
1,200 mm
flow rate
900 - 3,600 l/h
required nozzles
6 x 1/4" AG BSP jet: 15°
weight
44 kg
page 2, Vers. 2020-11
R+M / Suttner recommendation:
tip cleaner
High speed steel (HSS)
with aluminium shaft.
Length 42 mm
R+M Nr.
diameter
200 049 042
0.5