1.3.1 TERMINAL MAPPING FOR WIRING
ID
I
NITIALS
I
NPUT
1 (*)
DW+
2 (*)
COM
3 (*)
COM
4 (*)
UP+
5
JACK
8
HI-SPD
9
COM
10 Nero
0V
11 Nero
IN
12
16 (**)
DC 24V -
17 (**)
DC 24V+
L
ED
13
LED UP
14
ERR
15
LED DW
O
UTPUT
6
COM
7
VML
(*): The VMP "UP travel" input (n.3, n.4 clamps) and the VMD "DOWN travel" input (n.1,n.2 clamps) must never be active
at the same time. In the absence of the input signal of the upward command (VMP not included), produce throw a
normally open contact ("N.O." from the UP travel control panel switch) the UP signal input loss for the n.4- clamp and
connect for DC current the negative (COM) to n.3 clamp or in case of alternate current, the Neutral wire to n.3 clamp.
(**): if the control panel could not provide 24 VDC power, you should provide an optional power (24 V
2 INSTALLATION
2.1 INSTALLATION INSTRUCTION
1. Power off the control panel
2. Place the ETC device in the control panel on the DIN standard
guide
3. Perform the electrical wiring following the mapping according
to the type of device supplied (AC / DC)
4. Place the end of the thermal probe (black colored) in the
power unit tank.
Attention: the probe must be under the minimum fluid level of
the power unit, taking care to position it, far from the motor
windings and any heating resistors of the fluid.
e.g.: Place it on the outlet grid filter.
5. Move the leveling contacts, to obtain the same slow-down
levelling distance for all the stops (distance-set)
Note: you can get different distance-sets between UP and
DOWN travel according to the different speed between the two
directions.
6. Power ON the control panel and restart the system
7. Make an UP travel call and a DOWN travel call between two
floors (not extreme) to verify the operating.
8. ETC system will self-learn the operating conditions and it will
star the correct adjusting after 3-4 travels.
9. Let the system run regularly
,
INSTALLATION
USE AND MAINTENANCE MANUAL
D
Input of Down travel signal
Input of Up travel signal
Programming interface (Jack-in 3,5 mm)
Input of High speed signal
Thermal probe wire
Not used
DC 24V -
DC 24V +
Up travel
Error
Down travel
VML coil
ETC S
YSTEM
ESCRIPTION
ENG
9 / 12
V
ERSION
AC
DC
Phase
+ Positive
Neutral
- Negative
Neutral
- Negative
Phase
+ Positive
Phase
+ Positive
Neutral
- Negative
0V
IN
-
- Negative
+ Positive
Green
Yellow
Green
Neutral
- Negativo
Phase
+ Positivo
,1A)
DC
10991802 EN - 1.02 - 20.02.2019