INSTALLATION INSTRUCTIONS FOR ZONEMASTER™
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
For general ventilation control use only.
Do not use to control the flow of hazardous, corrosive, flammable or explosive materials and vapors.
Never expose this product to temperatures exceeding 140°F (60°C).
Always leave this product accessible for maintenance, cleaning and repair.
Before installing or servicing this product, switch power off at the service panel and lock service to prevent power from being switched on
accidentally.
Suncourt® Inc. assumes no responsibility for the installation of the ZoneMaster™.
Suncourt® does not provide electrical connection information beyond what is provided herein.
If in doubt, contact a competent contractor.
For your safety and protection follow all instructions and adhere to applicable building and electrical codes.
WARNING
To reduce the risk of fire, electric shock or injury to persons, observe all instructions. The ZoneMaster™ has been designed to operate on 24
Volt AC, 60 Hz. The only 110/120 Volt AC connection needed is for the power supply Transformer. Before installing the Transformer, confirm
that the electric power is off at the junction box where you will be making the Transformer 110/120 Volt connections. Observe the following
clearance to combustible materials or surfaces: For both the Transformer and the Damper electric motor: a minimum of 4" (10 cm) is required.
This damper is designed to control the flow of heated or cooled air in air distribution systems only. Never close more than 20% of the air ducts
leading to registers. The restricted airflow through a furnace or central air conditioner may cause failure of that equipment.This damper must
never be used to control the flow of combustion air, flue gas or other toxic or hazardous gases or applications where failure of the damper can
cause damage to persons, property or equipment and/or create a risk of fire, suffocation or death.
IMPORTANT NOTES
The following will be required to complete the installation:
• A standard low voltage Heat-Cool wall thermostat, designed for gas furnaces.
• Electrical wire, 2-conductor, 20 Gauge (CL-2 or Bell Wire) to connect the Transformer to the Damper via the wall thermostat. If the total length
of wire exceeds 80 feet (25 m), use 18 Gauge wire.
• A cover plate with knockout for the electrical box that the Transformer will be mounted on.
• If you are mounting the Damper between floor joists in flexible duct, you will need two duct supports.
• Aluminum foil duct tape.
BENEFITS
The ZoneMaster™ will allow you to individually control the temperature of a room in your home. e.g. An unused room does not
have to be heated or cooled to the same temperature as the remainder of the home. In the winter you may want a bedroom a
little cooler than the rest of the home. The baby's room you may want a little warmer than the rest of the home in the summertime. You control
your comfort and save significantly on energy use.
INSTALLATION INSTRUCTIONS
Consult the Wiring Diagram when planning the installation. Begin by determining the location of the Damper, the thermostat and the Low
Voltage Transformer. Then determine the route you will be running the wires from the Transformer to the thermostat and onwards to the
Damper. Once you have this planned, proceed as follows.
DAMPER UNIT INSTALLATION
For metal duct, remove a 6" (15 cm) section of duct at an existing joint so you will have one crimped duct end and one straight duct end. Slide
the Damper unit in place so that the ends are inserted at least 1" (2.5 cm) at each end. The Damper is non-directional so it may be installed
facing either direction of the airflow. Rotate the Damper so that you can easily access the electric terminal block. Complete the installation by
securing the Damper with the #6 sheet metal screws supplied. Finish the installation by covering the seams in the duct with a good quality
aluminum foil duct tape.
For flexible duct, cut the flexible duct and slide the ends over the ends of the Damper unit. You will need to support the Damper with a couple of
standard duct supports available at Home Centers. Complete the installation by securing the Damper to the flexible duct with a good quality
aluminum foil duct tape or nylon cable ties.
THERMOSTAT INSTALLATION: (THERMOSTAT NOT INCLUDED)
Mark the location of the thermostat mounting hole in the back plate of the thermostat and install the fastening hardware normally supplied with
the thermostat. Do not mount the thermostat on an outside wall. Locate the thermostat approximately 5' (1.5 m) above the floor and away from
drafts and direct sunlight. DO NOT screw the thermostat to the wall at this time.
WNT165-0312-A06
Tabla de contenido
loading

Resumen de contenidos para Suncourt ZONEMASTER

  • Página 1 WARNING To reduce the risk of fire, electric shock or injury to persons, observe all instructions. The ZoneMaster™ has been designed to operate on 24 Volt AC, 60 Hz. The only 110/120 Volt AC connection needed is for the power supply Transformer. Before installing the Transformer, confirm that the electric power is off at the junction box where you will be making the Transformer 110/120 Volt connections.
  • Página 2 Now review your installation. If you are positive that everything has been installed safely and securely, you may turn on the breaker on your house power panel. MAINTENANCE Suncourt® recommends that you clean your damper at regular intervals to keep it free from lint, dust and debris. The damper must never be exposed to temperatures over 140°F (60°C). OPERATING INSTRUCTIONS 1.
  • Página 3: Cinstrucciones De Instalación Para Zonemaster™ Lea Y Ahorre Estas Instrucciones

    ADVERTENCIA Para reducir el riesgo del fuego, la descarga eléctrica o lesión a las personas, observa todas las instrucciones. El ZoneMaster™ se ha diseñado funcionar encendido 24 VAC, 60 hertzios. La única conexión de 110/120 VAC necesitada está para el transformador de la fuente de alimentación.
  • Página 4: Advertencia Importante

    85°F o más baja, el válvula seguirá siendo cerrado. Si pasa a ALTO la temperatura en el cuarto que 85°F, el válvula se abrirá. (3) GARANTÍA DEL AÑO TRES Con sujeción a las siguientes limitaciones, la empresa fabricante, Suncourt Inc., garantiza que durante tres (3) años a partir de la fecha original de compra minorista, el ZoneMaster™...
  • Página 5 • Un couverture de boîte avec le poinçon dehors électrique que le transformateur sera assemblé dessus. • Si vous montez le ZoneMaster™ entre les poutrelles de plancher dans le conduit flexible, vous aurez besoin de 2 appuis de conduit. • Bande de conduit de adhésif d'aluminium.
  • Página 6: Consignes D'utilisation

    2. Saison De Chauffage: Placez le thermostat à la 'CHALEUR '. Ajustez alors le thermostat sur la température choisie (par exemple 55°F). Aussi longtemps que la température dans la chambre est 55°F ou plus haute, le ZoneMaster™ sera fermé. Si la température dans la chambre tombe au-dessous de 55°F, le ZoneMaster™...

Tabla de contenido