Tabla de contenido
Idiomas disponibles

Idiomas disponibles

8.Ordering Information

A
2
3
4
5
8
BC
05
10
11
09
14
13
12
18
E
1
2
3
V
0
1 PTC-M6L40.K1.5 (PTC Air Probe 1.5 mt Silicon Cable)
2
3
4
9
All order information of ESM-3710-N Temperature Controller are given on the table at above. User may
form appropriate device configuration from information and codes that at the table and convert it to the
ordering codes.Firstly, supply voltage then other specifications must be determined. Please fill the order
code blanks according to your needs.
Please contact us, if your needs are out of the standards.
Note-1:If input type is selected PTC or NTC (BC= 12, 18), Temperature sensor is given with the
device.For this reason, if input type is selected as PTC,sensor type (V = 0,1 or 2) or if input type is
selected as NTC, sensor type (V = 0,3 or 4) must be declared in ordering information.
c
Because of limited mechanical life of relay output contact, SSRoutput is recommended which
the device use PID control algoritm. The device with ON/OFF control algoritm, hysteresis
parameter must be set a suitable value for your system, to avoid too much relay switching.
c
Before commissioning the device, parameters must be set in accordance with desired use.
Incomplete or incorrect configuration can cause dangerous stiuations.
ESM-3710-N
(77x35 DIN Sizes)
Supply Voltage
24VW ( %15) 50/60Hz - 1.5VA
±
V ±
24V
( %15) 50/60Hz - 1.5VA
V ±
115V
( %15) 50/60Hz - 1.5VA
V ±
230V
( %15) 50/60Hz - 1.5VA
10 - 30 V Z
Input Type
J ,Fe CuNi IEC584.1(ITS90)
K ,NiCr Ni IEC584.1(ITS90)
PT 100, IEC751(ITS90)
PT 100, IEC751(ITS90
PT 1000, IEC751(ITS90)
PT 1000, IEC751(ITS90
PTC (Not-1)
NTC (Not-1)
Compressor Output
Relay Output (16(8) A@250 V V,at resistive Load, 1 NO,1NC )
SSR Driver Output (Maximum 20m, Maximum 17VZ )
Relay Output (30(15)A@240 V V,at resistive Load, 1 NO)
(Only valid for NTC Input Type devices)
Temp. Sensor which is given with ESM-3710-N
None
PTCS-M6L30.K1.5.1/8" (PTC Liquid Probe 1.5 mt Silicon Cable)
NTC-M5L20.K1.5
(NTC Sensor, thermoplastic moulded with 1.5 m cable for cooling application)
NTC-M6L50.K1.5
(
NTC Sensor, stainless steel housing with 1.5 m cable for cooling application)
Customer
A BC D E
/
FG HI /
0
/
00 00
Scale(°C)
0°C/32°F ; 800°C/1472°F
0°C/32°F ; 999°C/1830°F
-50°C/-58°F ;
-19.9°C/-4°F ;
-50°C/-58°F ;
-19.9°C/-4°F ;
-50°C/-58°F ;
-50°C/-58°F ;
U V W Z
/
1
0
0
400°C/752°F
99.9°C/212°F
400°C/752°F
99.9°C/212°F
150°C/302°F
100°C/212°F
14
Tabla de contenido
loading