Samsung DV405 Información Técnica página 4

Ocultar thumbs Ver también para DV405:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ALIGNMENT AND ADJUSTMENTS
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
Continuous Run Mode
Power On state
(Normal user mode)
How to enter:
-
Press Mixed Load Bell +Dry Level(DV405, DV398, DV395, DV393) or Wrinkle Prevent +
Time(DV231, DV365) for 7 sec during Power On State (normal user mode).
-
Once in Continuous Run Mode, display "cc" for 1 sec and finished cycle count for 1 sec and the
remaining time for 1 sec in turns.
-
The previous cycle will restart during Continuous Run Mode until the mode is deactivated.
-
During Continuous Run Mode, press Mixed Load Bell +Dry Level(DV405, DV398, DV395,
DV393) or Wrinkle Prevent + Time(DV231, DV365) for 7 seconds to go back to normal user
mode.
Data Display Mode (DV405, DV398, DV395, DV393 only)
How to Enter:
-
With Power On, press AdjustUp Key + AdjsutDown Key for 7 seconds until it sends out a
beeping sound .
-
If not pressed any keys for 5 minutes, it will be set back from Data Display Mode
-
If pressing AdjustUp Key in this mode, Display Mode will be incresed.
-
If pressing AdjustDown Key in this mode, Display Mode will be decresed.
Definition of Data Display Mode:
-
Display Mode 1 : Air Temperature data
-
Display Mode 2 : Average Touch Sensor data for 1 minute
-
Display Mode 3 : Average Temperature data for 1 minute
-
Display Mode 4 : Vent sensor temperature data (*DV398 Only)
(Technical)DV405-02365H-03_EN_130221.indd 4
WARNING
Mixed Load Bell +Dry Level(DV405, DV398, DV395, DV393)
or Wrinkle Prevent + Time(DV231, DV365) 7 SEC
4
Continuous Run Mode
2013-02-21
5:32:00
Tabla de contenido
loading

Este manual también es adecuado para:

Dv398Dv395Dv393Dv231Dv365

Tabla de contenido