POSITIONING OF THE FRONT FIXATION
Depending on the type of the gate (wood, iron, aluminium) the front fixation can be welded
or screwed (Fig. 6).
Mount the front fixation so that it guarantees the perfectly horizontal position of the
operator (Fig. 7).
N.B.: Ensure that when the door is fully open and fully closed the rod is not at the end of
its stroke, but is at least 15mm from the end of its stroke on each side.
Fix the IDRO and try several times to open and to close the gate, controlling that the cover
does not touch the moving gate, otherwise you have to readjust the ancorage on the gate.
In the case you have a wall parallel with the open gate, you must provide a niche in which
to place the operator.
IDRODUE 27
INSTALLATION OF THE CHROMIUM-PLATED ROD PROTECTION
Make sure to have inserted the antivibration plastic frame (A) before inserting the rod
cover extrusion (Fig. 8).
ELECTRICAL SAFETY DEVICES
In addition to compliance to all mechanical safety regulations, gates with leaf length
exceeding 1.8 m must be fitted with two pairs of photocells capable of interrupting gate
movement.
The photocells must be installed at a height of 40 - 60 cm between the gate posts on the
outside of the structure.
The other two photocells must be installed at the same height as the previous ones on the
ends of the gate leafs to form a barrier between the leafs when open.
Gate movement must be indicated by a flashing unit placed near the gate.
Use the T2 (for one or two single-phase motors) electronic control unit.
For connections and technical data of accessories refer to the appropriate booklets.
70 mm
46 mm
46 mm
PLASTIC RELEASE MOUNTING
ATTENTION: the mounting of the plastic release must be effectuated as shown in Fig. 9 only
and exsclusively after havingfinished all the instalaltion operations, mounting of the rod
cover and calibration of the by-pass valves.
70 mm
46 mm
BY-PASS VALVES COVER
8
21
70 mm
70 mm
70 mm
G
B