6.3. House security code

In most cases of use this code does not need to be changed.
If, however, for example, due to frequent false alarms, you suspect that neighbours in your area use alarm sys-
tems of the same type, you are recommended to change the house security code.
Important:
If you wish to make changes to the house security code,
siren, remote control, individual components).
All devices have a 4-polar jumper / DIP switch (usually in the battery compartment or under an additional cover).
Ensure that, later, all devices have exactly the same setting of this jumper. In this, the following applies:
ON
Inserted =
/ removed =
Jumper
for the house
code
DIP switch
for the house
code

7. ADDITION OF FURTHER COMPONENTS

Further components can be integrated into the system. Differing from the case of the starter set HG1000, it is
sufficient when the new components have the same house security code. This means that, upon purchase, further
components of the same jumper require the same PIN allocation as the system that was already used.
Zone allocation: This is not required in this system.
This allocation is required for the starter set HG1000, because work with safety zones takes place here. Remove
this jumper or plug this into your standard configuration.

8. OPERATION OF THE SYSTEM

After successful mounting of the components, the system can be used.
It has two main modes:
In order to activate the system (when, for example, you are leaving the house) simply press the
Now the countdown that has been set runs down and then the system activates.
If, for example, in your absence a break-in takes place (movement sensor or window contact is triggered) the
system alarm is triggered.
If, however, there was no break-in in your absence, simply and conveniently deactivate the system using the radio
remote control system, by pressing the
The system now switches into the standby mode.

9. TECHNICAL DATA

Outdoor siren (alarm centre)
Power supply
Siren dB
Maximum number of sensors
Operating frequency
House security code
Alarm duration
Switch-on delay
Housing
OFF
• Outdoor siren
• Sensors
Standard Code
1: ON, 2: ON, 3: ON, 4: ON
• Remote control
Standard Code
1: ON, 2: ON, 3: ON, 4: ON
Alarm mode
and
standby mode
button when you enter the house.
4x LR20 (D) batteries
120 dB
250
868.35 MHz (+/- 0.5 MHz)
Via 4-polar jumper
1/3/5 minutes (can be set)
5/30 seconds (can be set)
ABS plastic (waterproof)