PHB-SA Features
Sliding
guides
Clamp
knobs
Allen key
Height Adjustment
It allows adjustment for 3 heights between the PCB and the Heating Area of the PHB-A Heater Unit.
Low level
Medium level
High level
4
Adjustable slot clamps
for switching PCBs
Adjusting system
for changing height
28 mm
38 mm
48 mm
Changing PCBs of the same batch
The support lets you place PCBs of the same batch so as to always heat the same area.
Use the sliding guides to change the PCBs.
Removing the PCB
Loosen one sliding guide, pull back and lift out
the PCB.
Reworking large PCBs
Use the 4 caps to place larger PCBs than the PHB-SA Support or over 3mm thick.
Cap
Guide
PCB
1. Remove both guides by
2. Place the PCB on the 4
untightening the 8 screws.
rubber caps.
w w w.jbctools.com
Placing another PCB
Position it and tighten the sliding guide knobs.
3. The PCB is ready to work.