Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

INSTALLATION INSTRUCTIONS
PHOTOCELL OPTIONS
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l'alimentation
avant l'installation.
2.
This luminaire must be installed in accordance with the
NEC or your local electrical code. If you are not familiar
with these codes and requirements, consult a qualified
electrician.
Ce produit doit être installé conformément à NEC ou votre
code électrique local. Si vous n'êtes pas familier avec ces
codes et ces exigences, veuillez contacter un électricien
qualifié.
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
LOCATING KNOCKOUT
Locating knockout in an adjustable fitter:
a. Remove wiring compartment cover from adjustable fitter
using Phillips screwdriver.
b. Using a hammer and a punch, remove knockout of wiring
compartment cover. See Figure 1.
c. See photocontrol installations. (On backside)
FIGURE 1
FIGURE 1
Adjustable Fitter
E-ACP1EXT for use with 1000W 120V (Slip Fitter mounting
only):
a. Refer to Figure 2 and drill a 7/8" (22 mm) hole at the
knockout.
b. Remove nut from photocell.
following:
Knockout
Wiring Compartment
Cover
Photocontrol
www.e-conolight.com
Document:
LPN00674X0001A0
Created By:
TMT
c. Slide photocell through opening.
d. Attach nut, and secure in place.
e. Complete the wiring per wiring instructions.
f.
Slide Shield adjustment: slide open makes light turn on later/
off earlier. As slide covers "eye", lights will turn on earlier/off
later.
FIGURE 2
FIGURE 2
Locating knockout on directional flood junction box cover:
a. Using a hammer and a punch, remove knockout of wiring
compartment cover. See Figure 3.
b. See photocontrol installations. (on backside).
FIGURE 3
FIGURE 3
Locating knockout on E-WPC2:
a. Loosen (2) Phillips screws on bottom of lens frame.
b. Lift and remove lens frame.
c. Photocontrol knockout is located on the right side of housing
near the capacitor.
d. Using a hammer and a punch, remove knockout of wiring
compartment cover. See Figure 4.
e. Removal of the capacitor bracket may be required to install
the photocontrol.
f.
See photocontrol installations. (On backside).
Locating knockout on E-WPC1:
a. Loosen (2) Phillips screws on bottom of Lens Frame.
b. Lift and remove Lens Frame.
c. Photocontrol knockout is located on the lower right side of
housing by the reflector.
d. Remove reflector by removing (3) T-20 torx head screws.
Fold insulation (if installed) back out of the way for installation
of photocontrol.
e. Using a hammer and a punch, remove knock out of wiring
compartment. See Figure 5.
f.
See photocontrol installations.
g. If insulation is present under reflector, fold insulation over
photocontrol to provide shielding. The insulation has a U-slot
so that the insulation can slide between the photocontrol and
housing prior to tightening the thread nut.
h. Replace reflector and lens.
|
888.243.9445
|
FAX: 262.504.5409
Date
ECO#
Slide Shield
Photoeye
External Photocontrol
12-22-2019
011320
Tabla de contenido
loading

Resumen de contenidos para e-conolight E-ACP Serie

  • Página 1 Refer to Figure 2 and drill a 7/8” (22 mm) hole at the so that the insulation can slide between the photocontrol and knockout. housing prior to tightening the thread nut. b. Remove nut from photocell. h. Replace reflector and lens. www.e-conolight.com 888.243.9445 FAX: 262.504.5409...
  • Página 2 Figure 11 if wiring phase to phase. In all cases make sure the photocontrol voltage is rated for the supply voltage. 5. Reinstall any parts removed during the installation of the photocontrol. Driver Door FIGURE 8 Phillips Head Screws (Flat gasket in 1000W, 208-277V xtures) www.e-conolight.com 888.243.9445 FAX: 262.504.5409...
  • Página 3: Installation Instructions

    1. Wire according to Single Phase Voltage or Phase to Phase Voltage. FIGURE 10 FIGURE 11 SINGLE PHASE VOLTAGE PHASE TO PHASE VOLTAGE Voltage Voltage White White Neutral (COM) Ballast Ballast Black Black (COM) Driver Driver Neutral (COM) www.e-conolight.com 888.243.9445 FAX: 262.504.5409...
  • Página 4: Localizar El Orificio Prepunzonado

    Consulte la Figura 2 y perfore un orifi cio de 7/8” (22 mm) en apretar la tuerca roscada. la salida preparada h. Reemplace el refl ector y el lente. www.e-conolight.com 888.243.9445 FAX: 262.504.5409...
  • Página 5: Paquetes De Muro Sin Agujeros

    Puerta del controlador Junta Tórica Tornillos con cabeza (Empaque Plano en (Flat gasket in 1000W, Phillips Aparatos) de 1000 W y 208-277V xtures) 208-227 V Tuerca Fotocontrol Niple Roscado Cubierta del Compartimiento de Cables Pared Interna www.e-conolight.com 888.243.9445 FAX: 262.504.5409...
  • Página 6: Instalación Del Escudo

    VOLTAJE MONOFÁSICO SINGLE PHASE VOLTAGE PHASE TO PHASE VOLTAGE Voltaje Voltage Voltage Voltaje Rojo Rojo White White Blanco Blanco Neutral (COM) Ballast Ballast Negro Black Negro Black Balastra Balastra (COM) Driver Driver Neutral Vivo Vivo Vivo (COM) www.e-conolight.com 888.243.9445 FAX: 262.504.5409...
  • Página 7: Directives Importantes

    Consultez la Figure 2 et percez un trou de 22 mm (7/8 po) sur de serrer l'écrou fi leté. l'alvéole défonçable. h. Remettez en place le réfl ecteur et les lentilles. b. Enlevez l'écrou de la photocellule. www.e-conolight.com 888 243-9445 TÉLEC. : 262 504-5409...
  • Página 8 Porte de l’excitateur FIGURE 8 Vis à tête cruciforme Joint torique (rondelle plate dans les luminaires de Écrou 1 000 W, 208-277 V) Photocontrôle Manchon leté Couvercle du compartiment de câblage Mur intérieur www.e-conolight.com 888 243-9445 TÉLEC. : 262 504-5409...
  • Página 9: Installation De L'écran

    TENSION À PHASE UNIQUE TENSION PHASE-À-PHASE Tension Tension Rouge Rouge Blanc Blanc Neutral (COM) Ballast Ballast Noir Noir (COM) Circuit Circuit Sous Sous Neutre Sous de sortie de sortie (COM) tension tension tension www.e-conolight.com 888 243-9445 TÉLEC. : 262 504-5409...

Tabla de contenido