359, 392, 425, 458
1 Bit
360, 393, 426, 459
1 Bit
361, 394, 427, 460
1 Bit
1 Byte
362, 395, 428, 461
1 Byte
1 Byte
1 Byte
363, 396, 429, 462
1 Byte
1 Byte
1 Byte
364, 397, 430, 463
1 Byte
1 Byte
1 Byte
365, 398, 431, 464
1 Byte
1 Byte
1 Byte
366, 399, 432, 465
1 Byte
1 Byte
367, 400, 433, 466
1 Byte
1 Bit
368, 401, 434, 467
1 Bit
1 Bit
369, 402, 435, 468
1 Bit
370, 403, 436, 469
1 Bit
http://www.zennio.com
S
C T R - -
DPT_Switch
S
C T R - -
DPT_Switch
S
C T R - -
DPT_Switch
E
C - - W U
DPT_Value_1_Ucount
E
C - - W U
DPT_Value_1_Ucount
E
C - - W U
DPT_Value_1_Ucount
S
C T R - -
DPT_Value_1_Ucount
S
C T R - -
DPT_Value_1_Ucount
S
C T R - -
DPT_Value_1_Ucount
E
C - - W U
DPT_Scaling
E
C - - W U
DPT_Scaling
E
C - - W U
DPT_Scaling
S
C T R - -
DPT_Scaling
S
C T R - -
DPT_Scaling
S
C T R - -
DPT_Scaling
E
C - - W U
DPT_Scaling
E
C - - W U
DPT_Scaling
E
C - - W U
DPT_Scaling
E
C - - W U
DPT_Scaling
E
C - - W U
DPT_OpenClose
E
C - - W U
DPT_Switch
E
C - - W U
DPT_OpenClose
E
C - - W U
DPT_Switch
S
C T R - -
DPT_OpenClose
[FCz] Ventilador: velocidad 1
0/1
(estado)
[FCz] Ventilador: velocidad 2
0/1
(estado)
[FCz] Ventilador: velocidad 3
0/1
(estado)
[FCz] Ventilador manual: control
0 - 255
enumeración
[FCz] Ventilador manual: control
0 - 255
enumeración
[FCz] Ventilador manual: control
0 - 255
enumeración
[FCz] Ventilador: velocidad
0 - 255
enumeración (estado)
[FCz] Ventilador: velocidad
0 - 255
enumeración (estado)
[FCz] Ventilador: velocidad
0 - 255
enumeración (estado)
[FCz] Ventilador manual: control
0% - 100%
porcentaje
[FCz] Ventilador manual: control
0% - 100%
porcentaje
[FCz] Ventilador manual: control
0% - 100%
porcentaje
[FCz] Ventilador: velocidad
0% - 100%
porcentaje (estado)
[FCz] Ventilador: velocidad
0% - 100%
porcentaje (estado)
[FCz] Ventilador: velocidad
0% - 100%
porcentaje (estado)
[FCz] Ventilador enfriar: control
0% - 100%
continuo
[FCz] Válvula enfriar: control PI
0% - 100%
(continuo)
[FCz] Ventilador calentar: control
0% - 100%
continuo
[FCz] Válvula calentar: control PI
0% - 100%
(continuo)
[FCz] Válvula enfriar: control PWM
0/1
(1 bit)
[FCz] Válvula enfriar: control PWM
0/1
(1 bit)
[FCz] Válvula calentar: control
0/1
PWM (1 bit)
[FCz] Válvula calentar: control
0/1
PWM (1 bit)
0/1
[FCz] Válvula enfriar (estado)
MAXinBOX 16 Plus
0 = Off; 1 = On
0 = Off; 1 = On
0 = Off; 1 = On
0 = V0; 1 = V1; 2 = V2; 3 = V3
0 = V0; 1 = V1; 2 = V2
0 = V0; 1 = V1
V0 = 0; V1 = 1; V2 = 2; V3 = 3
V0 = 0; V1 = 1; V2 = 2
V0 = 0; V1 = 1
0% = V0; 1-33% = V1; 34-66% = V2; 67-
100% = V3
0% = V0; 1-50% = V1; 51-100% = V2
0% = V0; 1-100% = V1
V0 = 0%; V1 = 33,3%; V2 = 66,6%; V3 =
100%
V0 = 0%; V1 = 50,2%; V2 = 100%
V0 = 0%; V1 = 100%
0 - 100 %
0 - 100 %
0 - 100 %
0 - 100 %
0 = Abrir válvula; 1 = Cerrar válvula
0 = Cerrar válvula; 1 = Abrir válvula
0 = Abrir válvula; 1 = Cerrar válvula
0 = Cerrar válvula; 1 = Abrir válvula
0 = Abierta; 1 = Cerrada
Soporte técnico:
http://zennio.zendesk.com
19