4. OPERATING
-
Each CMU 100 incorporates a 2m long mains cable with IEC and earthed schucko
connector. Place the CMU 100 unit in a suitable position and connect it to an
adequate AC outlet.
-
Connect the first microphone of the chain using the 5m included cable to the GROUP
1 or 2 output. This first microphone can be delegate (WCM 10D) or chairman (WCM
10C). It is a daisy chain and the order of the microphones does not affect to their
operation.
-
Now connect the rest of microphones using the output connector of the previous one.
-
When the installation is complete and before switching on the system, check that all
the connections between microphones are correct and the in/out audio connections
of CMU 100.
-
Set the MIC MASTER knob to minimum.
-
Set the LIMIT SWITCH to the maximum number of the microphones to be active
simultaneously, with or without automatic function, selecting 1,3 or 6, the system will
shut off this number of microphones at any time.
-
For this function, the chairman microphone act as a normal microphone and is not
affect by the selection, it always will be ON.
-
The number of selection in AUTO side allows to shut off this quantity of delegates from
the chairman microphone. In the normal mode, this number of microphones will be
OFF after a period of 40s if there is no speech activity. Alternatively, delegates can
switch to OFF manually.
-
If the system operates correctly, adjust the MASTER MIC volume to a suitable level.