SAFETY PRECAUTIONS
- Always disconnect the power supply before making modifications to the device.
- The fitting and handling of these devices must be carried out by
- The wiring must run at least 40 cm away from any other wiring.
-
Do not overtighten the screws on the terminal block
-
Install the monitor in a dry protected location free from the risk of dripping or splashing water
-
Do not place in humid, dusty or smoky locations, or near sources of heat
- Before connecting the system to the mains, check the connections between the door panel,
power supply, distributors and monitors.
-
Always follow the instructions contained in this manual
( )
CHARACTERISTICS
*
-
Hands-free monitor
.
-
7" TFT colour screen
.
- Monitor with simple installation (unpolarised 2 wire BUS).
-
Touch screen for access and selection of menu functions
-
User menu
.
-
Installer's menu
.
-
Screen and volume settings menu
.
-
Start/stop communication capacitive touch switch
-
Menu access capacitive touch switch
.
-
Door release activation capacitive push button
-
Dip switches for setting the monitor address (call code)
SYSTEM OPERATION
-
To make a call, the visitor must press the button of the apartment; an a
confirming the call is in progress once the push button has been pressed
on. If vocal synthesis is activated then a "call
call
is
in progress
. At this moment the apartment's monitor receives the call During the call the
visitor can correct his call by pressing a push button corresponding to a different apartment, in
which case the original call is cancelled.
-
The
call lasts
for 40 seconds. Without alerting the visitor, their image appears on the master
monitor during this time. To view the picture on a slave monitor this function must first be
activated in the monitor
.
For
kit
villa
application
code 0 "apartment 1" or monitor with
address
receiving the call without the visitor being alerted.
If the call is not answered within 40 seconds, LED
- To establish communication, press the monitor's push button
turn on.
If the vocal synthesis is enabled the message "you can speak now" will be Heard
confirming the communication is activated.
-
Communication will last for one and a half minutes or until the push button
When communication has finished, LEDs
synthesis is activated then a "c
ommunication is
confirming the communication has finished.
- To open the door press the
push button during the call or communication processes: one
press will activate the
door
release for five seconds and LED
If vocal synthesis is activated then a "door is open" message will be heard in the door panel.
-
The descriptions of the function push buttons are found on page 3
( ) For more information, see the TTHERA GB2 user manual (code
*
"
https://doc.golmar.es/search/manual/50121889
authorised personnel
.
.
.
.
.
.
.
.
coustic tone will be heard
and
the
LED
will turn
is in progress
" message will
be heard confirming the
.
:
the image appears on the monitor (with
address
code 16 if the call is in "apartment 2") when
will turn off and the channel will be freed.
and the door panel's LED
is pressed again
and
will turn off and the
system
will be freed. If vocal
finished" message will
be heard in the door panel
will also turn on for five seconds.
.
50121889)".
2
THERA G 2
B MONITOR
MONITOR DESCRIPTION
( )
*
Micro SD
card
.
( )
*
Monitor address (code) setup:
1-apartment kit
2-apartment kit
APARTAMENT 1
APARTAMENT 1
THERA
THERA
CODE 0
CODE 0
( )
1
2-apartment kit: Monitor code 16 is the last,
dip 6 of the end of line to ON
MONITOR INSTALLATION
( )
*
will
Location
.
1.60m
( ) For more information, see the TTHERA GB2 user manual (code
*
https://doc.golmar.es/search/manual/50121889
7" TFT colour screen.
Start/stop communication push button.
During standby: Display the door
Menu access button.
Door release push button.
Microphone.
Monitor status light.
Attachment holes.
BUS connection terminals.
Con guration DIP switch.
ON
DIP
1
2
3
4
5
6
Connector.
Building
Dip6: Sets the end of line. Set to ON in monitors where the video cable
APARTAMENT 2
terminates. Remainder set to OFF.
THERA
Dip1
to
Dip5:
Set the monitor address (addresses 0 to 31).
Switches set to OFF have a value of zero.
The values of the switches set to ON are shown in the enclosed chart.
The monitor code will be the sum of the values of the switches set to ON.
( )
1
CODE 16
Value chart
Switch number: 1
2
3
ON
value
: 1
2
4
8 16
.
Surface
Embedding box
4 30
x
50121889)".
"
3
panel image
.
ON
DIP
4
5
1
2
3
4
5
6
E
xample
: 0 + 0+4+0+16 = 20
Screws supplied with
the embedding box.