MAnuAl On/OFF SAFety VAlVe/PilOt Kit
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
— Installation and service must be performed by
a qualified installer, service agency, or the gas
supplier.
WARNING: Improper installation, adjustment, al-
teration, service, or maintenance can cause injury or
property damage. Refer to this manual for correct in-
stallation and operational procedures. For assistance
or additional information consult a qualified installer,
service agency, or the gas supplier.
The GA9200 Series Manual On/Off Safety Valve/Pilot kit contains the following:
• Piezo Ignitor
• Manual Valve
• Pilot Burner (with natural gas
orifice)
• Piezo Ignitor Electrode
• Steel Shroud - Pilot Kit
• Control Dial Instructions
• Brass 3/8 FLR x 3/8 MPT Elbow
• Brass Fitting
• Pilot Bracket
GA9200 SerieS
For All ramp Pan Burner
natural and Propane/lP Gas logs
097159-04
901068-02
901069-01
901072-01
117106-01
901042-01
14264
14500
117107-01
Save this manual for future reference.
For more information, visit www.desatech.com
• Flex Connector
• 18" Propane/LP Brass Orifice 104506-22
• 24" Propane/LP Brass Orifice 104506-16
• 30" Propane/LP Brass Orifice 104506-30
• Propane/LP Pilot Burner Orifice 901070-01
• Screw 1/4" #8 "B" pt (6 ea.)
• Pilot Valve Control Dial
• Pilot Valve Dial Extension 3"
• Propane Conversion Decal
• Brass 3/8 FLR x 3/8 FPT Elbow
101628-01
901075-01
901079-01
901080-01
901691-01
14528
Tabla de contenido
loading

Resumen de contenidos para Desa Hearth Products GA9200 Serie

  • Página 1 GA9200 SerieS MAnuAl On/OFF SAFety VAlVe/PilOt Kit For All ramp Pan Burner natural and Propane/lP Gas logs WARNING: If the information in this manual is not fol- lowed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. —...
  • Página 2: Model Description

    inStAllAtiOn MODEL DESCRIPTION Btu Input Btu Input Minimum Natural Gas Propane/LP Gas Vent Opening LSLR18 18" Ramp Pan 60,000 50,000 8" (20.32 cm) SMS18 60,000 50,000 dia. BCS18 60,000 50,000 PHK18 60,000 50,000 LSLR24 24" Ramp Pan 80,000 70,000 8" (20.32 cm) SMS24 80,000 70,000 dia.
  • Página 3 inStAllAtiOn *A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable al- Continued ternative to test gauge connection. Purchase CHECK GAS TYPE the optional CSA design-certified equipment shutoff valve from your dealer. You must install this ON/OFF Safety Valve/ Pilot Kit if your gas type is propane/LP. For For propane/LP units, the installer must supply additional convenience and safety, this ON/ an external regulator.
  • Página 4 inStAllAtiOn We recommend that you install a sediment trap in supply line as shown in Figure 3. Continued Locate sediment trap where it is within reach Installation must include an equipment shut- for cleaning. Install in piping system between off valve, union, and plugged 1/8" NPT tap. fuel supply and appliance.
  • Página 5 inStAllAtiOn GA9200 SERIES ON/OFF SAFETy VALVE/PILOT KIT ASSEmBLy Continued Natural Gas Installation Test Pressures Equal To or Less Than 1. Locate air shutter at end of venturi tube 1/2 PSIG (3.5 kPa) where the orifice is mounted (see Figure 1. Close equipment shutoff valve (see 7). Loosen screw and adjust air shutter to Figure 4).
  • Página 6 inStAllAtiOn 2. Be sure to use the correct orifice for your appliance. The hardware kit contains Continued orifices for each respective size log set 6. Install the position decal and control knob as indicated by the model number on making sure to align the marks with the page 2. correct stop positions of the gas control. 3.
  • Página 7: To Turn Off Gas To Appliance

    inStAllAtiOn 6. With control knob pressed in, push down and release ignitor button. This Continued will light pilot. The pilot is attached to PILOT FLOW AdjUSTmENT the rear of the front burner. If needed, keep pressing ignitor button until pilot After installation is complete and the unit has lights.
  • Página 8: Warranty Information

    WArrAnty inFOrMAtiOn KeeP tHiS WArrAnty Model ______________________________ Serial No. ___________________________ Date Purchased ______________________ Always specify model and serial numbers when communicating with the factory. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied.
  • Página 9: La Instalación Y El Servicio Deben Ser Realizados

    Serie GA9200 PAquete de Piloto y válvulA de cierre de SeGuridAd mAnuAl Para todos los leños a gas natural y propano o gas lP en quemadores con charola en forma de rampa ADVERTENCIA: si no se sigue al pie de la letra la infor- mación contenida en este manual, se puede producir un incendio o una explosión que ocasione daños a la propiedad, lesiones personales o la muerte.
  • Página 10: Instalación

    inStAlAciÓn BTU de Abertura BTU de entrada MODELO DESCRIPCIÓN entrada mínima para Propano o gas LP gas natural ventilación LSLR18 Charola en 60,000 50,000 20.32 cm (8") SMS18 forma de 60,000 50,000 de diámetro BCS18 rampa de 18" 60,000 50,000 PHK18 60,000 50,000 LSLR24 Charola en 80,000 70,000...
  • Página 11: Verifique El Tipo De Gas

    inStAlAciÓn *Una válvula de cierre de equipo con diseño certificado por la CSA con rosca tipo NPT Continuación de 1/8" es una alternativa aceptable a la VERIFIqUE EL TIPO DE gAS conexión de medidor de prueba. Adquiera la Si el tipo de gas es propano o LP debe insta- válvula opcional de cierre de equipo certifica- lar este paquete de piloto y válvula de cierre da con diseño CSA del distribuidor.
  • Página 12: Pruebas De Presión En El Sistema De Tubería De Suministro De Gas

    inStAlAciÓn Se recomienda instalar una trampa de se- dimentos en la línea de suministro como se Continuación muestra en la figura 3. Coloque la trampa de La instalación debe incluir una válvula de sedimentos donde se pueda alcanz ar para cierre de equipo, la unión y el conector de su- limpiarla.
  • Página 13: Instalación Del Paquete De Piloto Y Válvula De Cierre De Seguridad Serie Ga9200

    inStAlAciÓn INSTALACIÓN DEL PAqUETE DE PILOTO y VÁLVULA DE CIERRE DE Continuación SEgURIDAD SERIE gA9200 6. Vuelva conectar el juego de leños y la válvu- la de cierre del equipo al suministro de gas. Instalación para gas natural Revise las conexiones que se volvieron a 1. Sitúe el obturador del aire al final del tubo ven- conectar en caso de fugas.
  • Página 14: Ajuste De Flujo Del Piloto

    inStAlAciÓn 2. Asegúrese de utilizar el orificio de tamaño correcto para el aparato. El paquete de fe- Continuación rretería contiene orificios para cada tamaño 9. Instale el tubo conector de gas al adaptador de juego de leños, como se indica por el de suministro de gas. Dé forma al tubo con número de modelo en la página 2.
  • Página 15: Cómo Cerrar El Suministro De Gas Al Aparato

    inStAlAciÓn gas para que realice las reparaciones ne- cesarias. Encienda el piloto con un fósforo Continuación hasta que se realicen las reparaciones. 7. Una vez que haya encendido el piloto mantenga la perilla de control presiona- Tornillo para da durante 30 segundos. Después de 30 ajustar el flujo segundos, suelte la perilla de control.
  • Página 16: Información De Garantía

    inFormAciÓn de GArAntÍA GuArde eStA GArAntÍA Modelo _______________________________ N° de serie ____________________________ Fecha de compra _______________________ Siempre especifique los números de modelo y de serie cuando se comunique con la fábrica. La única garantía aplicable es nuestra garantía estándar por escrito. No otorgamos ninguna otra garantía, expresa o implícita. GArAntÍA limitAdA PAquete de Piloto y válvulA de cierre de SeGuridAd Serie GA9200 DESA Heating, LLC garantiza que este producto está...

Tabla de contenido