TRouBleSHooTInG
Hand Dryer is not warm
Hand Dryer does not start
Hand Dryer will not shut off
SpecIfIcATIonS
model
Voltage/Frequency
IP Rating
Motor Rate/Type
Dimensions (w x d x h)
Weight
∙ P ossible defective heat element. Needs to be replaced. Call Royal
Sovereign customer service.
∙ N o power to the unit. Check the power to the unit
∙ D efective sensor - Replace the IR sensor. Call Royal Sovereign customer service.
∙ D efective motor - Replace the motor. Call Royal Sovereign customer service.
· The sensor is dirty or there is a reflection. Clean the IR Sensor.
Ensure that there is no possible reflection from another object.
RTHD-637SS
120 V, 60 Hz
25,000 RPM Brush Motor
30 x 21 x 20.5 cm (11.8 x 8.3 x 8.1lb)
3.8 kg (8.37 lb.)
7
RTHD-637SS
IP24