CLEANING
WARNING
Electrical Shock Hazard
Do not spray water or cleaning products. Liquid could contact
the electrical components and cause a short circuit or an
electrical shock.
CAUTION
Burn Hazard
Allow equipment to cool before moving or cleaning.

PREVENTATIVE MAINTENANCE

Contact an authorized service agent for a professional cleaning of the
components.
TROUBLESHOOTING
Problem
Toaster does not heat and the
conveyor does not move.
Toaster heats but one or both
conveyors do not work.
Toaster does not heat.
Toaster heat does not adjust after
changing the heat setting and
toaster is burning the buns.
Toaster repeatedly overheats.
Fan is not running.
Toaster is turned off and the fan is
running.
Vertical Contact Toaster Operator's Manual – Model CBT15
Might be Caused By
Toaster is not plugged in.
The wall breaker may be tripped.
The reset may be tripped.
The top cover may not be installed or
may be loose.
There may be a problem with the motor/
speed control or drive chain.
One or more heater elements may be
burned out or there may be a problem
with the heat control.
The heat relay may be defective.
The fan may be dirty.
There may be a problem with the fan.
There may be a problem with the fan or
fan switch.
Normal operation. The fan turns on as
needed to cool the toaster.
NOTICE: Do not use abrasive materials, scratching cleansers or
scouring pads to clean the exterior of the equipment.
These can damage the finish.

Daily Cleaning

1. Switch the power switch to the OFF position and unplug the toaster.
2. Let the toaster cool completely.
3. Remove the top cover and clean it with a soft cloth dampened with
warm water.
4. Use the dampened cloth to clean the exterior of the toaster and the
air intake on the side of the toaster and the collection tray.
Course of Action
Plug in the toaster.
Reset the breaker.
Look on the side of the toaster to see if an object is preventing the
fan blades from turning.
1. Remove the object.
2. Press the reset button on the back of the toaster. See "Features"
on page 2 for the location.
3. If the problem persists call Vollrath Technical Services.
Inspect the fan blades to see if they are dirty.
1. Switch the power switch to the OFF position.
2. Unplug the toaster.
3. Wait 30 minutes for the toaster cool.
4. Clean the fan blades.
5. Plug in the toaster.
6. Switch the power switch to the ON position.
7. Press the reset button.
8. If the problem persists call Vollrath Technical Services.
Inspect the cover to make sure it is properly installed. If the
problem persists call Vollrath Technical Services.
Contact Vollrath Technical Services.
Contact Vollrath Technical Services.
Verify the fan blades are clean.
Run the toaster for 10 minutes. If the fan does not run, contact
Vollrath Technical Services.
Run the toaster for 10 minutes. If the fan does not run, contact
Vollrath Technical Services.