3.3 Circuitry example for the operating mode Start/Stop
with control via an I/O module
Prerequisites
Operation with
the control panel
Operation via I/O
20
The starting program must be in the program
memory
Axis data, application data and hardware must
be set
The operating mode Start/Stop must be set
Activate the controller/enable the SPC200 with
a 1−signal at ENABLE
Start, Stop, Reset via the menu SYSTEM
CONTROL on the control panel
Start with a rising edge at START
Stop with a 0−signal at STOP
Continue program with 1−signal at STOP and
rising edge at START
Reset with 0−signal at STOP and rising edge at
START input
Switch off controller with a 0−signal at ENABLE
24 V
STOP (7)
START (8)
ENABLE (9)
READY (7)