MOUNTING THE THERMOSTAT'S
OUTLET BOX
IMPORTANT: To assure proper operation of the thermostat, it must not
become covered by insulation and must not be located adjacent to a
heat source.
Secure the thermostat outlet box with screws or nails through the mounting
bracket and into wall stud or rafter. Position flexible conduit so it does not
touch fan sleeve.
ADJUSTING THE THERMOSTAT
The unit is shipped from the factory with the thermostat set at 110°F. The fan
will automatically be turned on when the temperature in the attic reaches
110°F and will automatically be turned off when the temperature drops 10°F
below the set temperature. The "start" temperature setting may be adjusted to
any setting between 70° and 130°F.
WIRING
CAUTION: Be sure fan and switch are properly grounded and all wiring
complies with electrical code requirements for 120vAC, 15 amp circuit.
1. Refer to Figure 3. Run 120vAC wiring to the outlet box and secure with
standard box connector.
2. If desired, an on/off switch may be installed at a convenient location.
MAINTENANCE
CAUTION: Before cleaning or servicing unit, make sure power is
disconnected at service panel. (See important safety instructions
on page 1)
At the beginning of each ventilating season, check fan for any debris
that may be blocking fan blades, screen, or motor ventilation openings.
To extend motor life, lubricate motor at the beginning of each ventilating
season. Oil ports are located on the front and back of the motor. Use 5
or 6 drops of 20W non-detergent motor oil in each port.
WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period
of one (1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one year period, NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES, FILTERS, DUCT, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES
FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident,
improper maintenance or repair (other than by NuTone), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty
lasts, so the above limitation may not apply to you.
NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE'S OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS
WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may
not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
WARRANTY SERVICE: To qualify for warranty service, you must (a) notify NuTone at the address stated below or telephone 1/800-543-8687, (b) give the model
number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present
evidence of the original purchase date.
Date of Installation
Model No. and Product Description
Residents of Alaska or Hawaii should write to: NuTone Inc. Attn: Department of National Field Service, 4820 Red Bank Road, Cincinnati Ohio 45227-1599.
Residents of Canada should write to: Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario, Canada L5T 1H9.
One Year Limited Warranty
Builder or Installer
IF YOU NEED ASSISTANCE OR SERVICE:
For the location of your nearest NuTone Independent Authorized Service Center:
Residents of the contiguous United States Dial Free 1-800-543-8687
Please be prepared to provide:
Product model number • Date and Proof of purchase • The nature of the difficulty
GREEN GROUND
SCREW
THERMOSTAT
BLACK
WHITE
ATTIC AREA
LIVING AREA
ON/OFF
SWITCH
120vAC, 60Hz, 15 AMP CIRCUIT;
14 GAUGE WIRE
Product specifications subject to change without notice
4820 Red Bank Road, Cincinnati, Ohio 45227
Printed in U.S.A., Rev. 5/01, Part No. 87689
EARTH
GROUND
GREEN
BLACK
FAN
WHITE
MOTOR
EARTH
GROUND
FIGURE 3
Rev. 03/2001