TROUBLESHOOTING

PROBLEM
Motor will not start
Motor overheating and
cycling on and off
Pump/motor operates
function
Motor makes humming
noise but won't start
Low Water Flow
Water leaks
CAUSES
- Circuit breaker may be tripped
- Loose/Bad wire connection
- GFCI is tripped
- Incorrect electrical installation
- Jets are closed
- Lose/Bad wire connection
- Incorrect Amp usage
- Air supply to motor
- Jets are closed
- Suction/ strainer may be clogged
- Air valves are closed
- Jets are closed
- Pump does not have space
to operate
- Debris in pump
- Incorrect Amp usage
- Clogged pipe
- Incorrect electrical installation
- Leak in the plumbing
SOLUTION
- Make sure it is a 20 Amp circuit breaker with nothing else tied to the circuit
- Check for incorrect or lose wire connections, and pump/heater has
been properly grounded
- Reset if necessary
- Insure each motor/ in-line heater uses its own 20 Amp circuit breaker
and GFCI plug
- Make sure jets are fully operational and water is flowing
- Check for incorrect or loose wire connections
- Check for low voltage supply
- Make sure motor gets fresh air supply and vents are not clogged
- Open jets fully
- With pump off, remove the suction cover/strainer and remove any debris.
- Open all air control valves
- Make sure jets are fully open
- Make sure the motor shaft turns free
- Check for jammed impeller or an obstruction on the (volute) casing.
- Check for low voltage and undersized wire
- Check for clogged plumbing lines
- Check for low voltage
- Check compression fitting making sure they are properly aligned and
secured. Hand tighten only. Do not use any tools.
- Make sure the o-ring is properly seated and not damaged.