2. TECHNICAL CHARACTERISTICS
Quality control
cold water inlet, will be activated to ensure the safety of the appliance.
Characteristics table
Model
Power (W)
Power (W)
Voltage
(water
(water
(V)
inlet)
outlet)
ECO 30
800 W
1200 W
220-240 V~
ECO 50
800 W
1200 W
220-240 V~
ECO 80
800 W
1200 W
220-240 V~
Dimensions (mm)
ECO 30
A
470
B
586
C
250
D
355
E
183
F
302
G
262
Rated
Maximum
Electric Waterproof
pressure
temperature
type
grade
(MPa)
of water (ºC)
0.75 MPa
75 ºC
I
IPX4
0.75 MPa
75 ºC
I
IPX4
0.75 MPa
75 ºC
I
IPX4
G
ECO 50
ECO 80
470
530
871
1014
250
280
355
415
183
269
470
470
262
292
3. INSTALLATION OF THE ELECTRIC WATER HEATER
The following items are supplied with the electric water heater:
- 1 safety relief valve
- 2 electrolytic muffs
Location recommendations
This model is designed to be attached to a wall. In order to attach the water heater to
mended that you use the screws and rawl plugs which are supplied with the appliance.
The wall should be strong enough to bear twice the weight of the device filled with water,
otherwise it should be reinforced.
The electric water heater should be positioned as close as possible to the place where the
hot water will be used, in order to reduce the distance the hot water has to travel through
the pipes and thereby maintain its temperature.
The device should be positioned with at least 60 cm of clear space below the pipe outlets,
in order to facilitate any maintenance and/or repair which may need to be carried out.
This device is designed to be installed inside buildings which comply with current regula-
power surges.
or dust, or in gas-saturated environments.
ice could form.
sation may occur.
This water heater can be installed vertically or horizontally.
cold water inlet (blue) is below the hot water outlet (red).
It may be necessary to install a discharge pipe in order to remove any drops of water which
Hydraulic connection
– 5 –