Kenmore 233.5994090 Manual De Uso página 7

Ocultar thumbs Ver también para 233.5994090:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

CHANGING
BLOWER DISCHARGE
(Optional)
The blower is shipped with its discharge facing DOWN. Follow
these steps ONLY if:
the position of the blower discharge needs to be moved
so ductwork does not interfere with floor joists, plumbing
or wiring below.
it is necessary
to rotate the blower discharge to the
RIGHT or LEFT.
Place the unit on its back on a table or work surface.
DOWN DISCHARGE
= MOVING BLOWER LEFT OR RIGHT
1. Loosen the 4 nuts and 2 clamp channels.
2. Slide blower to desired position.
3. Use supplied cover plate to close open space (if any).
4. Tighten nuts to secure top of blower and use sheet metal
screws through bottom flange to secure bottom of blower.
CLAMP
CHAN N EL"_
NUTS
BLOWER
BOTTOM
FLANGE
LEFT OR RIGHT DISCHARGE
1. Remove the 4 nuts and 2 clamp channels.
2. Carefully lift blower and disconnect motor plug if necessary.
Reposition blower and RECONNECT
MOTOR PLUG.
3. Use supplied cover plate to close open space (if any).
4. Replace clamp channels and use nuts to secure the blower
in its new position.
5. Use sheet metal screws through bottom flange to secure
bottom of blower.
NUT
, BLOWE
R
MOTOR
COVER
PLATE
2
¢b
3'
€.Q
O_
7
Tabla de contenido
loading

Este manual también es adecuado para:

233.5994690

Tabla de contenido