Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

1PH Non-Clog Starter Kit
The FPS Non-Clog Pump Starter Kit, item number 520851, contains the start/run components required for
the proper operation of the single phase 3NC Series and 4NC series non-clog pumps. The FPS single phase
control panels are designed to operate the 230 V Non-Clog pumps.
The starter kit contains the following components (one of each unless otherwise noted):
Oil-filled run capacitor, 50 MFD/370 VAC, No. 950519
Aluminum electrolytic start capacitor, 270-324 MFD/330 VAC, with attached 15k-ohm bleed-off resis-
tor, No. 275468119
Start (potential) relay, No. 950542
Please inspect the starter kit and verify the components/parts included are as listed. Figures of each item
are shown in the replacement parts list.
The FPS Non-Clog Pump Starter Kit has been designed specifically for use with the Single Phase 3NC Series
and 4NC Series non-clog pumps. This specific set of components has not been designed for operation with
other pump models of similarly, components designed for use with other pump manufacturers and models
are not applicable for use with the FPS pumps.
This product is covered by a Limited Warranty for a period of 24 months from the date of original purchase
by the consumer. For complete warranty information, refer to www.franklinengineered.com; or, contact
Customer Support for a printed copy.
SAFETY INSTRUCTIONS
Before Getting Started
This equipment should be installed and serviced by technically
qualified personnel who are familiar with the correct selection
and use of appropriate tools, equipment, and procedures. Failure
to comply with national and local electrical and plumbing codes
and within Little Giant recommendations may result in electrical
shock or fire hazard, unsatisfactory performance, or equipment
failure.
Know the product's application, limitations, and potential haz-
ards. Read and follow instructions carefully to avoid injury and
property damage. Do not disassemble or repair unit unless
described in this manual.
Refer to product data plate(s) for additional precautions, operat-
ing instructions and specifications.
Failure to follow installation or operation procedures and all
applicable codes may result in the following hazards:
MANUAL
Risk of death, personal injury, or
property damage due to explosion, fire,
or electric shock.
Do not use to pump flammable or explosive fluids such as
gasoline, fuel oil, kerosene, etc.
Do not use in explosive atmospheres or hazardous loca-
tions as classified by the NEC, ANSI/NFPA70.
Do not handle a pump or pump motor with wet hands or
when standing on a wet or damp surface, or in water.
When a pump is in its application, do not touch the motor,
pipes, or water until the unit is unplugged or electrically
disconnected.
If the power disconnect is out of sight, lock it in the open posi-
tion and tag it to prevent unexpected application of power.
If the disconnect panel is not accessible, contact the elec-
tric company to stop service.
English
EN
Tabla de contenido
loading

Resumen de contenidos para FPS 520851

  • Página 1 The FPS Non-Clog Pump Starter Kit, item number 520851, contains the start/run components required for the proper operation of the single phase 3NC Series and 4NC series non-clog pumps. The FPS single phase control panels are designed to operate the 230 V Non-Clog pumps.
  • Página 2: Safety Instructions

    SAFETY INSTRUCTIONS Before Getting Started Risk of severe injury or death by Risk of bodily injury, electric shock, electrical shock. or equipment damage. • To reduce risk of electrical shock, disconnect power before • This appliance can be used by children aged from 8 years and working on or around the system.
  • Página 3: Physical Installation

    INSTALLATION Physical Installation INSTALLATION Physical Installation High voltages capable of causing severe injury or death by electrical shock are present in this unit. • Disconnect all power before installing the Starter Kit, servicing the pump, or servicing the control panel. The included run capacitor, start capacitor, and potential relay must be installed as shown in the start/run circuitry diagram.
  • Página 4: Replacement Parts List

    Replacement Parts List Item Part Number Description Quantity 950542 Relay, Start (Potential), 500 VAC 275468119 Capacitor, 297 MFD, 330 VAC 950519 Capacitor, 50 MFD, 370 VAC For technical assistance, parts, or repair, please contact: 800.348.2420 | franklinengineered.com Form 998782 Rev. 000 11/19 Copyright © 2019, Franklin Electric, Co., Inc. All rights reserved.
  • Página 5: Kit De Arranque De Bomba Sumergible Monofásica Sin Obstrucción

    El kit de arranque de la bomba no obstrucción FPS ha sido diseñado específicamente para su uso con las bombas de la serie monofási- cas 3NC y las bombas no obstructivas de las series 4NC. Este conjunto específico de componentes no ha sido diseñado para funcionar con otros modelos de bombas de igual, componentes diseñados para su uso con otros fabricantes de bombas y los modelos no son...
  • Página 6 INSTRUCCIONES SOBRE SEGURIDAD Antes de empezar Esta unidad tiene voltajes elevados que Riesgo de lesiones corporales, son capaces de provocar lesiones graves descargas eléctricas o daños al o muerte por descarga eléctrica. equipo. • Para reducir el riesgo de descarga eléctrica, desconecte la •...
  • Página 7: Installación

    INSTALLACIÓN Instalación fisica INSTALLACIÓN Instalación fisica Esta unidad tiene voltajes elevados que son capaces de provocar lesiones graves o muerte por descarga eléctrica. • Para minimizar el riesgo de descarga eléctrica, desconecte la energía antes de trabajar en o alrededor del sistema El condensador de funcionamiento, condensador de arranque y relé...
  • Página 8: Piezas De Repuesto

    Piezas de repuesto ELEMENTO PIEZA # Description CANT. RELÉ DE POTENCIAL DE ARRANQUE, 950542 500 VAC 275468119 CONDENSADOR, 297 MFD, 330 VAC 950519 CONDENSADOR, 50 MFD, 370 VAC Para la ayuda técnica, por favor póngase en contacto: 800.348.2420 | franklinengineered.com Form 998779 Rev. 000 11/19 Copyright ©...
  • Página 9: Kit De Démarrage Submersible De Pompe Non Obstruer En Phase Unique

    Kit de démarrage submersible de pompe non obstruer en phase unique Le kit FPS Non-engorgeables le Kit de Démarreur, numéro d’article 520851, contient les composantes com- mencent/dirigent exigées pour l'opération nécessaire du 3NC la Série et 4NC la série non-engorgeables des pompes.
  • Página 10 CONSIGNES DE SÉCURITÉ Avant de commencer Cet appareil contient des tensions élevées Risque de blessure, de choc électrique susceptibles d’entraîner par choc électrique ou de dégâts matériels des blessures graves ou la mort • Cet équipement ne doit pas être utilisé par des enfants ou •...
  • Página 11: Installation Physique

    INSTALLATION Installation physique INSTALLATION Installation physique De hauts voltages capables de provoquer la blessure sévère ou la mort par le choc électrique sont présents dans cette unité. • Débrancher toutes les sources de courant avant d’installer l’ensemble de démarreur ou de faire l’entretien de la pompe ou du panneau de contrôle.
  • Página 12: Piéces De Rechange

    Piéces de rechange Item Pièce # Description Qté 950542 RELAIS, POTENTIEL DE DÉMARRAGE, 500 V c.a. 275468119 CONDENSATEUR, 297 MFD, 330 V c.a. 950519 CONDENSATEUR, 50 MFD, 370 V c.a. Pour l’aide technique, entrez s’il vous plaît en contact : 800.348.2420 | franklinengineered.com Form 998779 Rev.

Tabla de contenido