Lenze L-force 8400 motec E82ZBU Instrucciones Para El Montaje página 5

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Parameterise the drive unit
(Lenze setting bold)
1. Activate DIP1, DIP2 and P1, P2, P3.
2. Assign the "Drive Ready" device state signal to the output DO1 (Lenze setting).
DIP1
Description
DIP1, DIP2, P1, P2, P3
Device status
Drive Ready:
Drive Fail:
3. Set the rated motor frequency of the connected motor.
4. Select the mode of the analog input.
Permissible setting: 0 … 10 V or 0 … 20 mA.
5. Select control mode 16.
The change of direction of rotation is controlled via the digital input terminals.
DIP2
Description
Rated motor frequency
Mode of the analog input
Control mode of technology application
(cf. selection C00007)
)
Note!
If preset setpoints are activated via DI1 and DI2, the setpoint selection via the
potentiometer is deactivated. The control via the switch remains unchanged.
6. Set acceleration and deceleration time of the motor.
P3
Description
Acceleration and deceleration time of the motor in
seconds
EDK84DZEBUxx DE/EN/FR/ES/IT 1.0
¸
1
Active
ON
Inactive
OFF
DO1 = HIGH
NO/COM = Closed
1
50 Hz
OFF
60 Hz
ON
87 Hz
OFF
120 Hz
ON
0 ... 10 V
0 ... 20 mA
9 (local mode)
16 (terminals 16)
0
[s]
0.1
5
Switch
2
3
4
Switch position is not relevant
Switch position is not relevant
Switch
2
3
4
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
Setting
1
2
3
4
5
0.5
1
2
5
10
5
6
7
8
OFF
5
6
7
8
OFF
OFF
OFF
ON
6
7
8
9
20
30
60
120
l
Tabla de contenido
loading

Tabla de contenido