Extension Cords; Voltage And Circuit Protection - Craftsman 919.167320 El Manual Del Propietario

Ocultar thumbs Ver también para 919.167320:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Extension Cords

Using extension cords is not recom-
mended. The use of extension cords
will cause voltage to drop resulting
in power loss to the motor and over-
heating.
Instead of using an extension cord,
increase the working reach of the
air hose by attaching another length
of hose to its end. Attach additional
lengths of hose as needed.
If an extension cord must be used, be
sure it is:
a 3-wire extension cord that has
a 3-blade grounding plug, and a
3-slot receptacle that will accept
the plug on the product
in good condition
no longer than 50 feet
12 gauge (AWG) or larger. (Wire
size increases as gauge number
decreases. 10 AWG and 8 AWG
may also be used. DO NOT USE
14 OR 16 AWG.)

Voltage and Circuit Protection

Refer to the specification chart for the
voltage and minimum branch circuit
requirements.
operated on a 15 amp circuit if the
following conditions are met.
1.
Voltage supply to circuit must
comply with the National
Electrical Code.
2.
Circuit is not used to supply any
other electrical needs.
3.
Extension cords comply with
specifications.
4.
Circuit is equipped with a 15
amp circuit breaker or 15 amp
time delay fuse. NOTE: If com-
pressor is connected to a circuit
protected by fuses, use only time
delay fuses. Time delay fuses
should be marked "D" in Canada
and "T" in the US.
If any of the above conditions can-
not be met, or if operation of the
compressor repeatedly causes inter-
ruption of the power, it may be nec-
essary to operate it from a 20 amp
circuit. It is not necessary to change
the cord set.
11- ENG
Certain air com-
pressors can be
A10819

Capítulos

Tabla de contenido
loading

Tabla de contenido