LCD Hourly Programmable
Thermostat
Code: 0769007, Reference: KT7-LCD-P
A. Installation, Mounting:
Caution: Turn off 0769007 and the electronic devices (e.g.
heater,cooler) which will be connected before installation start. It is
highly recommended that the installation procedure is processed by
trained personnel.
1. Installation Location:
Choose an indoor location that provides good temperature
detection. Prevent direct exposure to sunlight; at low air circulation, near heat/cool
generating sources, or suffer from great temperature changes (e.g. near door).
2. Wiring:
There are 3 wiring terminals at the top-right corner at the back of 0769007, labeled as
"L"(Live), "H"(Heater) and "C" (Cooler). "H" and "C" are input to heater and cooler.
Leaves unused hole blank.
DO NOT CHANGE OR EXCHANGE ANY WIRINGS.
3. Mounting:
Using the accessory screws and wall anchors provided, mount the thermostat with the
key-hole at the back. The thermostat should be mounted on the wall as shown in Figure 1.
Figure 1
4. Slide Switch at Back and HEAT/COOL Slide Switch:
In Winter put the HEAT/COOL slide switch at HEAT, while in summer set it at COOL.
The slide switch at Back set the minimum off time of the heater/cooler:
HEAT
COOL
NO DELAY
10sec
5min
DELAY
5min
5min
Note: When COOL is set, the minimum off time is fixed at 5 min.
When the switch is in the OFF mode, middle position on the slide switch, even when the
rotating symbol could be shown, the device state is OFF.
B. Start/Reset:
1.
After wiring, mounting and switch off all connected devices, place 2 pieces of new AA
1.5V alkaline batteries according to the polarities marked. LCD display will be
switched on.
2.
In case the thermostat does not turn on accordingly, press 'RST' to reset.
3.
Switch ON the heater/cooler. The heater/cooler will remain at OFF until LT08 activate
the output ON with
rotating.
C. Normal Time Mode:
LCD displays the time, room temperature, program number and output status.
D. Time Setting Mode:
1.
Press <
>, Day of Week (1-7) will flash, press <▲>/<▼> to select Day of Week.
2.
Press <
>, Hour will flash, press <▲>/<▼ > to adjust Hour.
3.
Press <
>, Minute will flash, press <▲>/<▼ > to adjust Minute.
4.
Press <
> jump back to Normal Time Mode, or auto return after 10 seconds.
5.
Jumper selection for 12/24 HR display can be selected at the PCB during installation,
factory pre-set at 24 HR.
E. Factory Defined Programs: FTY PROG (0-6,8), USER PROG
(10-16,18)
F. Set Program Time:
1.
Press <PRG>, Day of Week (1-7) will flash, press <▲>/<▼ > to select Day of Week.
2.
Press <PRG>, Program Nos. P (0-6,8,10-16,18) will flash, press <▲>/<▼ > to select
Program nos.
3.
Press <
>/<
> will select the Comfort/Economy mode for each Hour Bar in user
programs (10-16,18).
4.
Press <
> to jump back to Normal Time Mode, or auto return after 10 seconds.
G.Comfort and Economy Temperature Setting:
1.
Hold <
>/<
> for 1 sec will enter Comfort and Economy Temperature Setting
mode.
2.
Press <▲>/<▼> to adjust different temperature.
3.
Press <
> to jump back to Normal Time Mode, or auto-return after 10 sec.
H. Temporary Override Mode:
1.
Temporary Override Mode can change the current program mode to the opposite
program mode temporarily. The time when the next program of opposite state or
the next day is reached, Temporary Override mode will be released automatically.
2.
At <
> mode, press <
displayed; or at <
with
displayed.
3.
Follow section G to adjust setting temperature if necessary.
4.
Temporary Override mode will automatically release when the time reaches the
opposite of <
5.
To release Temporary Override mode manually, press <
opposite of <
I. Comfort and Economy Hold Timer:
1.
Comfort/Economy Hold Timer can force the thermostat to run at Comfort/Economy
mode for a defined period of time.
2.
Hold <
> for 1 second will see setting temperature flashing, press <
will enter the Comfort Hold Timer
<
> for 1 second will see setting temperature flashing, press <
the Economy Hold Timer
3.
Press <▲>/<▼> to adjust the number of hours for hold timer.
4.
Press <
(Defined Program)
after 10 sec.
5.
Follow section G to adjust the setting temperature in necessary.
(Defined Program)
6.
Press <
>/<
(Defined Program)
J. Special Conditions:
1.
If battery level is LOW, "C", "P", & ":" will be flashing, the recent batteries must be
(Defined Program)
replaced with new one.
2.
When room temperature is below 5°C, Defrost 'df' is displayed. Heat output will
(Defined Program)
turn ON and Cool output will turn OFF.
(Whole Day Comfort
3.
Below 0°C, L is displayed. Heat output will turn ON and Cool output will turn OFF.
mode)
4.
Above 39.5°C, H is displayed. Heat output will turn OFF and Cool output will turn
ON.
(Whole Day
K. Specification:
Economy mode)
1.
Temperature measurement:
(Defrost Program)
2.
Accuracy:
3.
Temperature control range:
4.
Temperature detection:
5.
Switching voltage:
6.
Switching current:
7.
Terminals:
8.
Electronic control:
9.
Battery:
10.
Operating temperature:
11.
Storage temperature:
12.
Operating humidity:
TEMPER ENERGY INTERNATIONAL S.L.
Polígono industrial de Granda, nave 18
33199 • Granda - Siero • Asturias
Teléfono: (+34) 902 201 292
Fax: (+34) 902 201 303
www.grupotemper.com
> will enter the Temporary Override mode with
> mode, press <
> will enter the Temporary Override mode
>/<
> state, or when the next day is met.
>/<
>/<
> state.
with flashing. On the other hand, hold
> again will enter
with flashing.
> to confirm setting and back to Normal Time Mode, or auto return
> key of the opposite state can release the Hold Timer.
0.0 - 39.5 °C
± 0.5 °C
5.0 - 35.0 °C
10 sec.
24...250VAC 50/60Hz
8A max Resistive
2
2.5 mm
cable
Type 2.B action
2 x 1.5V AA alkaline
-10 - 50 °C
-20 - 60 °C
5-90% non-condensing