sPeCIFICATIoNs
LCB20NT, HDB20NT
• Btu (Variable): 10,000/20,000 Btu/Hr
• Type Gas: Natural Only
• Ignition: Piezo
• Pressure Regulator Setting: 3" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 10.5" W.C., Minimum - 4" W.C.
LCB30NT, HDB30NT
• Btu (Variable): 15,000/30,000 Btu/Hr
• Type Gas: Natural Only
• Ignition: Piezo
• Pressure Regulator Setting: 3" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 10.5" W.C., Minimum - 4" W.C.
LCB20PT, HDB20PT
• Btu (Variable): 10,000/20,000 Btu/Hr
• Type Gas: Propane/LP Only
• Ignition: Piezo
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 14" W.C., Minimum - 11" W.C.
LCB30PT, HDB30PT
• Btu (Variable): 15,000/30,000 Btu/Hr
• Type Gas: Propane/LP Only
• Ignition: Piezo
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure (in. of water):
Maximum - 14" W.C., Minimum - 11" W.C.
seRVICe HINTs
When Gas Pressure Is Too Low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If
so, contact your local natural or propane/LP
gas supplier.
121254-01A
RePlACeMeNT PARTs
PARTS
Contact Allparts Equipment & Accessories Inc.
at 1-877-475-5660
When calling Allparts Equipment & Accessories
have ready
• model number of your heater
• the replacement part number
www.allpartsinc.com
23