Installation to Solid Concrete surface

• When installing Peerless ceiling mounts on a concrete ceiling, the ceiling must be at least 8" thick with a minimum
compressive strength of 2000 psi. Never attach concrete expansion anchors to concrete covered with plaster,
drywall, or other finishing material.
• For attachment to concrete floor only. All eight concrete expansion anchors must be used.
• Tighten to 35 ft. • lb (47 N.M.) maximum torque.
Use support column (A) as a template to mark eight mounting holes on concrete floor. Drill eight 3/8" (10 mm) dia.
1
pilot holes to a minimum depth of 3" (76 mm) as shown. Place support column over mounting holes and secure
with eight concrete expansion anchors (B) as shown below. Tighten all fasteners.
WARNING
Tighten all fasteners. Tighten to 35 ft. • lb (47 N.M.) maximum
torque.
A
B
4 of 32
A
ISSUED: 06-22-10 SHEET #: 061-9053-7 07-08-15
concrete
floor
B