6.3 Direction of rotation. ATTENTION.
Ensure that the motor shaft turns freely; do not start the pump
if is blocked. For this purpose, electropumps have a groove at
the end of the shaft, on the ventilator side, which permits it to
be turned manually using a screwdriver (fig 1 page 11 ).
In triphase motors, the impeller, (pag.16-17 nº8) can be
unscrewed if the motors starts in the opposite direction.
Counter-rotation can even damage the mechanical seal. Start
the motor for a few seconds and check that the direction of
rotation coincides with that indicated by the arrow on the
ventilator cover. Should this not be the case, it is absolutely
necessary to advise the authorised installer (invert the phase
connection).
6.4 ATTENTION.
Check that motor does not exceed the amperage indicate on
the nameplate rating other wise, regulate using the header
valve.
7- MAINTENANCE / CONSERVATION
Before touching, disconnect the electricity supply.
7.1 BCP model – ATTENTION -
Check and clean the filter basket regularly (pag.17 Nº18 )
To remove the prefilter place the selection valve as well as all
other valves in the closed position. Take out the prefilter cover
(17) remove the basket and clean it under running water. To
avoid any deterioration, do not strike it. To replace the prefilter
basket introduce it until its original position. Place the seal (17)
on the cover and grease it with Vaseline. The transparent
cover must be cleaned with water and neutral soap. "Do not
use solvents and do not introduce chemical products inside".
7.1
BC model – ATTENTION –
If the pump is switched off during a long period of time or
should there be any danger of frost, the hydraulic casing (page
16 Nº5) must be emptied, by loosening the outlet together with
its o'ring seal (14). Before starting the pump fit the outlet and
its o'ring seal. Fill the pump with water and check it with a
screwdriver that the motor is not jammed. (Fig.1 Pag.11), If the
shaft has seized up, call a qualified technician. In case of the
motor flooding, do not start it. Call an electrician who will
dismantle the motor in order to dry it.
7.2 ATTENTION. If the pump is switched off for long periods
of time, should there be a danger of frost, the pump casing
(pag.16-17 nº5) should be emptied, by loosening the two
emptying outlets (14) along with their O-ring seals.
Before starting the pump, replace the outlets (14) and their O-
ring seals. Fill the pump chamber with water and check with a
screwdriver that the motor is not jammed. If the shaft has
seized up, call a qualified technician. In the event of the motor
flooding, do not try to start it; call an electrician to dismount the
motor in order to the dry it.
FIBERPOOL INTERNACIONAL
8.DISMOUNTING
operation, all valves must be in the "off" position: having
checked this:
8.2. ATTENTION -
electropump, see detail drawing (pag.16-17). To remove the
motor from the hydraulic casing, remove the six screws and
the two screws, and take out the motor set with the impeller
(9).
In order to dismantle the impeller (9) we will remove the screw
and its o-ring using an Allen key Nº 8, this way the impeller (9)
will be loose. By doing this operation the mechanical seal will
be loose as well as the diffuser (8).
9-ASSEMPLY
ATTENTION.
"All parts to be assembled must be clean and in perfect
condition for use".
- Assemble the mechanical seal (pag. 16-17 nº10-11);
assemble the rotary part of the seal (10) above the back flange
of the impeller (9) by pressing until this falls into the space. By
this way we will obtain the union of the two parts of the seal.
The retainer has been previously lubricated with water.
- Assemble the impeller (9) on the shaft fixed by a screw using
an Allen key Nº 8.
- We have to take in mind that the diffuser (8) flange as well as
the seals (7,12) must be fit into the correct space at the point
of union between the pump and the motor.
10 – SPARE PARTS
To order any spare parts, indications must be given of the
denomination, number shown on the detail drawing (pages16
to 23) and nameplate.
8.1 ATTENTION.
-
Disconnect the general electricity switch and the
differential switch (this must be done by an authorized
specialist)
Loosen and remove the supply cables on the
-
bushings box (40, mod TT) (29, mod TR).
Release the aspiration and return sleeves.
-
-
Empty the pump.
To dismantle and assemble the
Before performing any
7