1. Attach a 3-wire commercial grade extension cord to a GFCI protected service and plug the other end into the outlet
under the Access Cover of the KNAACK PowerCrew located on the outside of the jobsite storage box.
2. A red light (LED) on the face of the KNAACK PowerCrew will glow red indicating power is available.
3. Test GFCI function of KNAACK PowerCrew:
A. Red LED light is on.
B. Press the TEST button. The RESET button should pop out and the red LED light should go off.
C. Press the RESET button. The RESET button should stay in and the red LED light should come back on.
D. The GFCI is operating correctly and KNAACK PowerCrew is ready to use.
E. If the GFCI fails to operate as described above, refer to the Trouble Shooting Guide.
4. For added protection, the KNAACK PowerCrew has an internal relay which senses an open neutral condition in the
supply and stays open, preventing electricity from reaching a person who might be in contact with a broken wire.
5. SUGGESTED USE: KNAACK PowerCrew can supply simultaneous power to 4 devices as long as the total
amperage added together is 15 amps (1800 watts) or less. Typically, this will allow battery charging for tools and
medium duty tool operation at the jobsite storage box.
6. Fused Outlets: KNAACK PowerCrew is equipped with a 15AMP time delay fuse. Should a short circuit occur, it will
blow, or open, and disconnect power to the outlets.
Problem
No power being delivered
to items plugged into the
KNAACK PowerCrew unit.
Unit appears damaged
(cracked).
Red LED is NOT lit and the
GFCI is reset and there is no
power to the outlets.
This LIMITED WARRANTY is made by Knaack LLC, 420 E. Terra Cotta Ave., Crystal Lake, Illinois to the original retail purchaser of KNAACK® or WEATHER GUARD®
products.
KNAACK LLC WARRANTS THAT KNAACK OR WEATHER GUARD PRODUCTS WILL BE FREE FROM DEFECTS IN MATERIAL AND WORKMANSHIP FOR A
PERIOD OF THREE (3) YEARS FROM DATE OF PURCHASE BY THE ORIGINAL RETAIL PURCHASER.
If, before the expiration of the Warranty period, purchaser discovers that the KNAACK or WEATHER GUARD product fails to fulfill the Warranty, purchaser shall
contact Knaack LLC to make arrangements for an inspection of the product. If Knaack LLC determines a defect exists, Knaack LLC shall, at its option and expense,
repair or replace any defective part. All Warranty repairs shall be made by an authorized KNAACK Product dealer or Knaack LLC approved service company.
This Warranty shall not apply if the KNAACK or WEATHER GUARD product has been subjected to misuse, abnormal service or handling, improper maintenance, or
alterations made by anyone other than a KNAACK or WEATHER GUARD Product dealer or a Knaack LLC approved service company.
THE WARRANTY PRINTED ABOVE IS THE ONLY WARRANTY APPLICABLE TO THIS PURCHASE. ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
KNAACK LLC SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF ANY BREACH OF THIS WARRANTY. NOR
SHALL THE DAMAGES EXCEED THE RETURN AMOUNT OF THE PURCHASE PRICE PAID BY THE ORIGINAL PURCHASER.
This Warranty is in lieu of all Warranties express or implied. The terms of this Warranty shall not be modified by any party, their successors or assigns. This Warranty
gives you specific legal rights, and you may also have other rights which vary from state to state.
USE OF KNAACK® PowerCrew™
TROUBLE SHOOTING GUIDE
Resolution
Look to see if the red LED light is glowing on the
KNAACK PowerCrew housing.
If not, ensure the supply extension cord is properly plugged into the inlet plug of the
KNAACK PowerCrew unit.
Push the RESET button on the GFCI outlet to reset.
If loads are removed from outlets and the reset still does not stay pushed in, then
there is a problem with the GFCI. Remove KNAACK PowerCrew from service.
There are no user-serviceable parts inside.
Immediately and carefully unplug the extension cord from the power source and
remove the KNAACK PowerCrew unit from service.
Push GFCI test button. If reset button does not pop out then check fuse. Twist the
fuse holder cap counter-clockwise to open. If fuse is blown, replace with a 15 AMP
time-delay fuse (KNAACK Part Number 70113).