POWER SUPPLY
Always use thermomagnetic circuit breakers together with differential circuit breakers.
The wiring shall comply according with the Standards for buildings. The nominal section of the
power supply line conductors for the electric outlet shall comply with the directives of standards
considering the nominal current, the total length until the power consumption point and the
correction factors for cabling grouping shall be verified.
Cable (mm2)
1,5
2,5
4,0
Values taken from the standard for cables in conduits.
IMPORTANT:
The conductors current capacity shall NEVER be less than the thermomagnetic circuit
breaker capacity.
It is not recommended to install two single-phase thermomagnetic circuit breakers in
this case.
Before plug in the equipment, check if the outlet polarity is the same as the one shown
in the equipment data sheet.
TABLE 2
RATED VOLTS
AMPS
WALL
OUTLET
FUSE
SIZE
TIME DELAY
FUSE
(or Circuit
Breaker)
Max. Amps (A)
13
18
24
RECEPTACLE AND FUSE TYPES
125
250
15
20
15
20
15
20
15
20
Plug
Plug
Cartridge
8
Recommended Fuse (A)
250
30
10
20
30
30
15
20
30
Used on
Argentina only
16
20
25
16
15
used
on
Europe